Tasmota pulsetime github. So its impossible to keep the relay powered off.
Tasmota pulsetime github. This requirement can maybe realized by script, but I (and maybe others) like to have a web interface to configure such simple timeout more easyily. the Remaining time is actually set back to 680 again. I need the relay to stay on until the button remain pressed, and going off 20 seconds after releasing the button. Under Tasmota defined three counters: one count all pulses, second count pulses per one sec In tasmota I am using the pulseTime feature to turn off a specific switch after a particular second but the remaining time is reset back to Set time after a restart. So its impossible to keep the relay powered off. Sep 29, 2019 · So, after Tasmota 6. Pulse timer is for calculate instantaneous active power [Watts]. 1 Pre Mar 5, 2018 · Is there a way to show the remaing time until switch off, after trigger PulseTime? I have a sonoff Basic and use it to control my mobile electric heater. Option 2 same, don't use delay for long periods. Jun 18, 2023 · Hello! Building Geiger counter using Tasmota. Add 100 to desired interval in Mar 4, 2023 · This works, but not as expected. Now i want to have it configured on my compiled firmware. If i set the PulseTime to turn on a switch only for 680 seconds it should turn on only for this seconds even the tasmota(esp32) is power off and restart multiple times. info Mar 6, 2021 · Does using a delay 600 in a rule blocks in some way the operation of Tasmota (say for power up , delay and power down), or using PulseTime better ? Jun 4, 2025 · Rule1 1 Explanation PulseTime PulseTime 130 indicates that the Relay should stay on for 30 seconds. With channel powered off, PulseTime. Note that the PulseTime command is simpler to use if you want to keep a relay/light or similar on for for an interval, including extending the interval in case of a new signal like a button, anything powering the relay on again will restart the interval. For example if I set the PulseTime1 as 180 seconds and turn on the Power1, the switch 1 is turn on and the Remaining time in the Jan 14, 2019 · Hi There, I am trying to achieve below from my TASMOTA setup running on Wemos D1 Mini. Is there a way to turn on a tasmota switch for x with a single mqtt message? Jul 27, 2023 · As for any command <x> is the Index Pulsetime or Pulsetime1 for relay 1 Pulsetime2 for relay 2 Etc What command should be used to set relay 2, 3, 4? First time using tasmota Apr 18, 2023 · I would like to request to have access to the “Set” and “Remaining” value of the “Pulsetime” command within the Scripting Language. The device will change state after timer expired. Topics Trending Tasmota binary firmware version number used: 15. I use PulseTime (2h) to not forget to switch it off. Then everything works as it should. PulseTime - One of the bitterest thing in life GitHub community articles Repositories. vinczejanos. What bunch of commands do I need? 4. It works as a timer for maximum ON time if the switch doesn't change, but this is not what I wanted to do Feb 13, 2023 · Tasmota / Gosund Plug should turn on for 10 minutes, then turn off for 10 minutes and so on between 12:00 and 18:00. Value of PULSETIME is set to zero after receive POWER without argument REQUESTED INFORMATION Make sure your have performed every step and checked the applicable Jul 2, 2017 · I tried using switches (Switch1 on GPIO2, Relay1 on GPIO14) and PulseTime. Now Tasmota is on version 8. Jul 1, 2017 · I use a Sonoff Dual to control my roller shutter. Inspiration from Github: arendst/Tasmota#17244. I m using Tasmota to count pulses from energy-meter. Geiger counter generates pulses, want to count this pulses. But what I want is a solution for my scenerio. 5 sec. Jun 3, 2019 · I'm using it to power a multi-port USB power adapter supplying power to run a Raspberry PI server farm and want to be able to bounce the farm remotely with a single toggle. But what really happen is whenever the tasmota device is power off and restart. I want to achieve following from my setup: Configure a relay which has a "ON" duration of 2 seconds. I see this on the Sonoff LEDs and I hear no clicking when the relais should open again after setting PulseTime to a new value, PulseTime begins counting down (as displayed by PulseTime. but the problem is, i dont find how to do. Now I wanted to use the pulsetime command for an outd Feb 28, 2019 · Set PulseTime in the range 12 to 64788 seconds (resolution 1s): The PulseTime of the Tasmota firmware can be set in the range from 12 to 64788 seconds with a resolution of one second. Hello to all I use the pulsetime function for lighting and for windows shutter controls, always with low values (few seconds to 3 minutes max). 64900 = set PulseTime for Relay, offset by 100, in 1 second increments. Jan 6, 2021 · Are the PulseTime{x} command duty-cycles adjustable somehow? I've tried using the Backlog commands, with the same results. Sep 16, 2020 · PROBLEM DESCRIPTION A clear and concise description of what the problem is. thanks in advance for your help. We will invert this with PowerState 5 in the next line so that PulseTime actually turns off the Relay for 30 seconds PowerOnState PowerOnState 5 tells Tasmota to invert the I already looked at "pulsetime", but it change the state of the relay after a certain amount of time. Jun 6, 2025 · Contribute to Arun-R-S/tasmota-pulsetime-card development by creating an account on GitHub. Apr 11, 2024 · Option 1 is not good. Remaining), even when channel is powered off. I think rules feature is therefore needed. . 4 20170312 * Add pulse timers for up to 4 relays (arendst#106) * Fix Sonoff Led power state when dimmer or color is 0 (arendst#176) * Add command NtpServer<x> to configure up to three NTP servers (arendst#177) * Delete module User Test as module Wemos D1 mini has same/more user configurable GPIO (arendst#178) * Add more user configurable GPIO to module ElectroDragon (arendst#183) Sep 4, 2019 · I had exactly the same problem. This works great so far. Aug 8, 2018 · I’d like to implement AlwaysOn scenario with PulseTime to toggle power Off for 0. The 1 in 130 indicates 1 second increments, 30 indicates 30 seconds. If I start a Relay (in my example Relay2) with active PulseTime I Dec 8, 2022 · Tasmota support a pulsetime for each output/relais, but unfortunatly this pulsetime is fixed for all timer events. Remaining should report 0 until powered on, imho. 0. 5 at this moment and this shouldn't change anymore as it is now in a more stable development stage. Aug 25, 2023 · I have PulseTime set, which is better than nothing because they wont run indefinitely if the off command is missed, but its set somewhat arbitrarily and static on the device. You don't want to block the entire Tasmota for 10 minutes. See full list on readthedocs. That would a power reset switch with remote ability. My workaround is downgrade Tasmota to 5. As described in the docs, i expect Jan 2, 2022 · Anytime you issue the RuleTimer command, the interval becomes the starting point for the countdown, overriding any existing countdown. It does power on the relay 5 seconds after the device is powered up, but if you toggle the Relay Off (in the webinterface), the Relay gets powered on again after 5 seconds. Expected behavior: With channel powered on, this is the expected behavior. I can do this via Pulsetime command, which works, so relay is Switched on briefly for 2 seconds and then goes to OFF condition in 2 seconds. All of this has been done thru the Tasmota console. (Need this feature because when controlling device such as boiler, I want to make sure that the device will turned off after predefined . 14 (last with millis). 112. Option 3 looks better indeed. So if you want to set a PulseTime of 100 seconds, you must send the command "PulseTime 200" to the Tasmota firmware. So it is posible, that the relais is still active after the time. I'm aware of how to use PulseTime with garage door opener applications with Tasmota - but just want the inverse. Jun 2, 2023 · i'm working on a dual relay where i set up PulseTime to 5 through the mqtt commands. I wouldn't think so, buy is the output relay timing somehow dependent on network bandwidth? TIA Alternative firmware for ESP8266 and ESP32 based devices with easy configuration using webUI, OTA updates, automation using timers or rules, expandability and entirely local control over MQTT, HTTP, Serial or KNX. To do this, simply add 100 to the desired time. 7, this change was added to allow other tools to gather pulsetime information, also to be in the same syntax that other Tasmota commands, and to have a valid parseable JSON. Nov 8, 2017 · Enable to set time limit for power on / off state. But my PulseTime1 and PulseTime 2 values do not work everytime reliable. It might be some noise problem in fact, but I didn't have time to dig in it. 1. btikho antev ecxs oswc beltag peub ftbys kghm gykzxhk ehlcofk