Home

Nimble network configuration

  • Nimble network configuration. It contains all the network parameter settings on an array, including: Network configuration profiles; IP addresses; Subnets; Routes; Network interfaces Procedure. 58 You can delete an existing Draft network configuration profile. For a specific cabling guide, see . Oct 13, 2016 · Nimble Setup Manager scans the subnet for unconfigured Nimble arrays. If more than one switch is used in this configuration, the switches must be connected to each other by an inter-switch link or trunk port, or they must be configured in a single switch stack if supported by the switch manufacturer. Configuring the FC switch is the most crucial and error-prone task in the storage provisioning process. Check the HPE Nimble Storage array in the following order: Review the volume configuration by navigating to Manage > Volumes and selecting the volume that you created. Network Considerations. This host will not know which array to contact. After you have finished creating a new network configuration using the Draft profile, you can promote it to be the Active profile. Feb 9, 2010 · hpe_nimble_network module – Manage the HPE Nimble Storage network configuration The advanced network configuration allows the greatest flexibility to suit your network traffic and advanced multipath requirements. The host also connects to both switches. Nimble has now dedicated “Networking” tab available in the administration menu where the Group or individual arrays can be changed. Ansible 2. You can make changes to (edit) all three profiles while the array is running. This solution illustrates the direct attach cabling option and presents the Nimble Storage appliance closest to the UCS servers – blade or rack series. 9 or later; Python 3. Open File Transfer. Accessing the CLI. Other arrays will forward the info to that array resulting in latency. Verify that the proper initiator group is assigned to the volume. From VMware vCenter using the vSphere web client, navigate to the datacenter (for example, SmartStack) and cluster (for example, SS-AppVMCluster-CVD700) where the host resides. 3 years ago Updated. Note that only one management connection and one data connection are shown. Check the number of connected initiators to verify that all initiators are connected. 24 The Array Command Line Interface. If you select Cloud Replication, enter the credentials for your volume. To establish base FC connectivity between an HPE Nimble Storage array and your VMware compute environment, all components must have a supported FC configuration, including: To access ESXi configurations verified by HPE, see the HPE InfoSight Validated Configuration Matrix. Studios can rapidly onboard and collaborate with artists globally and create content faster with access to virtual workstations, high-speed storage, and scalable rendering across the AWS global infrastructure. conf file. Proper network architecture and configuration are vital to ensuring that deployment is successful and that enterprise workloads gain the most value from the solution. Configuration worksheet: Appendix A: Configuration Worksheets: Be sure to fill out your worksheets before starting deployment. The advanced configuration uses the maximum number of data connections on the iSCSI network, to obtain the best availability and throughput. Click Save as Draft. Solution cabling: HPE ProLiant Network Card Configuration; HPE Nimble Storage Network Card Configuration; Server, Array, and Switch Cabling ExampleCabling the network, storage, and server components c. It contains all the network parameter settings on an array, including: Network configuration profiles; IP addresses; Subnets; Routes; Network interfaces Deploying dHCI . 0 or later; Parameters After you have finished creating a new network configuration using the Draft profile, you can promote it to be the Active profile. support contact information: Toll-free: 1-877-3NIMBLE (877-364-6253), extension 2 Local: 408-432-9600, extension 2 Email: support@nimblestorage. After you click OK, you can add more initiators if you need to. traffic assignments. Maximum rated input current: 11A at 100-120V. Choose Administration > Network . Subnet mask or CIDR: Enter the subnet mask of the management network. When the Active profile is revised, by being edited or replaced by the Draft, the previous revision becomes the Backup profile. e. Select a replication type. Depending on which model of HPE Nimble Storage array you have, there are upgrade paths for the controllers and cache drives. Parameters fails. password (True, str, None) HPE Nimble Storage password. These can be found in Manage -> Arrays or Administration -> Network Configuration -> Interfaces. Click General for the Settings Summary. Note: You can also click Configure Draft Settings or View Backup Settings to configure an interface in the Jan 21, 2021 · HPE Nimble dHCI Configuration Checker. Python 3. The HPE Nimble Storage SDK for Python provides a Pythonic client library to interact with the HPE Nimble Storage REST API. plan for configuration of IP addresses. • Integration and certification with major hypervisors, applications, and infrastructure components. Our system indicated that 66 rules were checked, and we had 2 Errors. On the General page, click one of the following: Configure Draft Settings or. HPE Nimble Storage Array. The solution is a decentralized AI orchestration network (aka. and Storage Adapters link. 0 or later, make configuration changes, and switch to the automatic method. Gateway address: Enter the gateway for the management network. HPE Nimble Storage dHCI has simplified A network configuration enables a Nimble Storage array to be accessed and managed from the network, communicate with other arrays in a group, carry data traffic, and replicate volumes. Choose either: Previous topic: Task 11: Uplink Cisco Nexus Switches Into the Existing Network Infrastructure Appendix E: Resources The section Finding More Information contains pointers that can be helpful as you are configuring and using dHCI. However, the new component is more powerful or has greater capacity. Peter Mason. For more information about cabling, refer to the Nimble Storage Quick Start Guide for your arrays. Enable an Active Directory Domain. 2. The ability to manage VVols using VMware virtual disks mapped to native storage containers is a new feature in vSphere 6. An example of network connections for two dedicated networks. When the Active profile is revised, by being edited or replaced by the Draft configuration, the previous Active profile becomes the Backup profile. It contains all the network parameter settings on an array, including: Network configuration profiles; IP addresses; Subnets; Routes; Network interfaces Using the GUI, record the WWPNs for each target port on the Nimble Storage array. HPE Nimble Storage array with two 10 Gbps ports on each controller Figure: An example of an HPE Nimble Storage HF or AF array with two 10 Gbps iSCSI ports on each controller Server, Array, and Switch Cabling Example Parent topic : Setting up the System Previous topic : Cabling for Array OS Versions 6. In the Windows Start menu, click Nimble Storage > Nimble Setup Manager . f. iSCSI connections from initiator repeatedly closed by array due to improper target IP configuration. Running the configuration checker will verify that your dHCI deployment is set up correctly. Check the checkbox nest to an existing subnet and click Edit to change its settings. You should always consult the documentation specific to your switches and other components. Topics: •? Use a secure shell (SSH) utility to log in to the management IP of a Nimble array to run administrative commands. 168. Choose Save. Not all procedures can be performed with both the CLI and the GUI. host (True, str, None) HPE Nimble Storage IP address. If three HTTPS POST attempts are made and they all fail, these Nimble Administrative Commands A wide variety of administrative commands are provided to configure, manage, and monitor HPE Nimble Storage arrays. HF20, HF20C, HF20H, HF40, HF40C, HF60, HF60C models. For network connectivity, the user must create a new VMkernel portgroup to configure the vSwitch for IP storage access. AI OrderBook) that connects applications, developers, GPU resources and data on the blockchain for efficient, low cost and permissionless AI model training and inferencing. HPE Nimble Storage SDK for Python. Group Information. (Groups are used to manage up to 4 arrays and pool storage. A Draft network configuration profile is created if one does not already exist. identify options for subnets, including (for iSCSI): discovery IP addressing. The MIB is a virtual database developed by the IETF/IEEE, as well as device providers like Nimble Storage, that ensures a standard method of viewing network management information on devices from different Install the Array Use this procedure to install the following HPE Nimble Storage array models: AF20, AF20Q, AF40, AF60, and AF80. Procedure. Nimble OS $ netconfig --activate --force_ip_update Set up the initial configuration on HPE FlexFabric switches 1 and 2 through the serial port: 1If you are using serial cable to connect to the console, specify 9600 baud as the required speed. In this configuration, the management and data traffic share the same physical network interfaces. You can add or remove an iSCSI interface to or from one or more subnets. Select one of the uninitialized arrays from the Nimble Setup Manager list and click Next. HPE Nimble Storage dHCI has increased the scale of servers supported from 20 to 32 nodes within a single Nimble dHCI cluster. Requirements. Routine storage management operations can be completed in minutes. Requirements The below requirements are needed on the host that executes this module. Jun 16, 2020 · Re: Nimble on Windows. . Install the HPE Nimble Storage Array. Click Make Active. Use either the NimbleOS graphical user interface (GUI) or the command line interface (CLI) to perform administrative operations on an HPE Nimble Storage array or group of arrays. Note: If the array is not visible in Nimble Setup Manager, verify that the array is on the same subnet as the Windows host. 2Interconnect the two switches by using QSFP+ or SFP+, depending on the switch model. Nimble Connection Manager (NCM) is designed to simplify making and maintaining the optimal number of iSCSI connections (also known iSCSI sessions) between the Windows host and Nimble array. Select the array to configure and click Next. You can add more connections and use different ports as needed. Maintenance IP address 1: Enter a primary maintenance IP address on the management network. Enter the array name, group name, network settings, and admin password, then click Next. </dd>\n<dt>secondary_mgmt_ip (False, str, None)</dt>\n<dd>Secondary management IP address for the Group. HPE Alletra 5010, 5010H, 5030, 5030H, 5050 models. The parameter descriptions are tagged for easier navigation and classification, and each description has the necessary steps to apply the Network Configuration Manager helps maintain versions of device configurations in a secure, centralized repository and manage them from a single interface. One Shared Network. There are several steps to install the HPE Nimble Storage array, such as providing a suitable operating environment, installing the array into your rack, and making network connections appropriate to your current and anticipated topologies. FIGURE 1. On a small number of setups, you may need to add some additional configuration to your firewall and/or content filter should you run into difficulties. Elevate your storage experience with all HPE Nimble storage flash array storage that’s radically simple, built for cloud and guaranteed to deliver 99. Diifferent configurations can require different setup steps. Scale-out The Manual method is provided for legacy applications to upgrade to NimbleOS 2. In more advanced configurations, you can define your own network configuration to handle the desired I/O flow. VMware Virtual Volumes. Configure the subnet settings. Click Edit, then click the Subnets tab. VMware virtual volumes (vVols) allow you to manage virtual machines (VMs) and their data (such as VMDKs and physical disks) without having to know details about the underlying storage. On the General page, click one of the following: Configure Draft Settings or; View Backup Settings; Click Make Active. When you configure zoning, be sure to double-check all configurations. * An array sends DNA messages using HTTPS POST back to Nimble Storage Support, if it is enabled. This Nimble Streamer Configuration Parameters Reference page provides information on how to control the behavior of a Nimble Streamer instance. It contains all the network parameter settings on an array, including: Network configuration profiles; IP addresses; Subnets; Routes; Network interfaces Configure an iSCSI Interface. Click Configure Active Settings to configure an interface in the Active network configuration profile. Regulatory model number NMBLA-0002-1200. 6 or later; HPE Nimble Storage SDK for Python; HPE Nimble Storage arrays running NimbleOS 5. The selected network configuration Jan 6, 2015 · In this post I’m going to document some of the setup required to meet the best practices outlined in Nimble’s Networking Best Practices Guide when setting up your system with redundant NX-OS switches. With the release of custom configuration components The NimbleOS lets you manage the objects in a storage system: volumes and their associated clones, replicas, and snapshots. Clones are writable, highly space-efficient copies of volumes which you can create from snapshots. Grouping multiple arrays so that they can be managed as one entity provides significant manageability benefits, because it appears as if you are managing a single large array. Use the tools provided by the switch vendor to configure zoning for the fabric. These SNMP objects are stored in a MIB. 45 Network Configuration. d. Go to the Start Menu and search for File Transfer. 9999% availability. Configure IP Addresses; Subnets. The advanced network configuration allows the greatest flexibility to suit your network traffic and advanced multipath requirements. Another innovative feature in the plugin is the dHCI Configuration Checker. In the Veeam Backup & Replication console, navigate to the Storage Infrastructure tab, add the Nimble array and enter the array IP/DNS and credentials: Then, configure a backup proxy by specifying the access option (I chose an iSCSI for my lab), and run the setup. The NCM feature is designed for arrays running NimbleOS 2. Performance and capacity scale linearly as you add arrays to the group. However, if you have NCM (Nimble Connection Manager) is installed in the Host, NCM will take care of Automatic MPIO configuration and path management. In the Information dialog, click OK. 0. About the Nimble Command Line Interface (CLI) Run Nimble administrative commands from the command line interface (CLI) to configure and monitor a Nimble Storage array. Single-initiator zoning is an industry best practice. The network config operation. validate (False, bool, None) Validate a network configuration. The Activate draft configuration dialog box is displayed. Hardware Guide – HFxx or Hardware Guide - AFxx. Power supplies. Choose Administration > Network. CLI Administration Guide - Hewlett Packard Enterprise Domains. Firewall/content filter configuration. Most Nimble customers can use Nimble straight out-of-the-box without any configuration required to their network. • Manage storage at VM-level granularity using VMware vVols or through a vCenter plugin. Aug 20, 2020 · For your convenience, the following is the U. Highlight the iSCSI Software Adapter and copy the iSCSI Name. The confirmation dialogs for the Backup configuration and the Draft configuration are different. In this configuration, the Nimble Storage connects directly to unified 10G ports on the Cisco UCS Fabric Interconnect FI (UPN-6248) devices. Jun 3, 2016 · To support vMotion in the SmartStack design, complete the following configuration steps for each host in the cluster. Ensure that the iSCSI storage is configured to export a LUN accessible to the vSphere host iSCSI initiators on a trusted network. 5. Your role determines your This guide describes switch and network requirements and best practices for the HPE Nimble Storage dHCI solution. IP address zones. Oct 21, 2013 · The network configuration on the array is easily configured. S. 6 or later. Do one of the following: Click Add to configure a new subnet. Scale-out, often referred to as horizontal scaling, means adding arrays to a group. At the FC Switch: Configure FC Access. 7A at 200-240V. On each array, an SNMP agent provides information about the network configuration and operations. Repetitive tasks such as switch VLAN configuration, optimizing switch performance at scale with best practices, and cabling validation are now automated, which saves time and avoids The following configuration illustrates this method. Before you begin Attention If you are installing more than one HPE Nimble Storage array, refer to the Hardware Guide available on HPE InfoSight for information about your model. After the array has been configured, you can perform maintenance Click on the Configuration tab. Figure: An example of advanced network configuration: data connections Feb 14, 2022 · Amazon Nimble Studio empowers creative studios to produce visual effects, animation, and interactive content entirely in the cloud. On the General page, click either Configure Draft Settings or View Backup Settings. com. This Additionally, GPU and data providers can monetize their participation in the Nimble Network. Click either Configure Active Settings or View Backup Settings. Proper network configuration of the HPE Nimble Storage array enables high availability and supports uninterrupted access to monitoring functions and array data. 201 Nimble OS $ netconfig --validate INFO: Configuration is valid. HPE Nimble Storage arrays running NimbleOS 5. This particular example shows the management and data paths on different networks. Check array cabling. Enter the studio ID that you found in the Set up a studio in Nimble Studio tutorial. Target audience HPE Nimble Storage network card configuration Figure 1 shows the MGMT and iSCSI ports. When you create a clone from a snapshot, you create a new volume with a new name and iSCSI or Fibre Channel target with the Manage the storage network configuration on the HPE Nimble Storage group. In preparation for installing your Nimble array, information in this section will help you: determine your network topology. Use a data subnet discovery IP address to connect from the host to the array. The separated management and data paths on this network provide higher performance and high availability. For hosts that don’t have an NCM with 2. 120. Use this information to configure local ports for incoming and outgoing HTTP, HTTPS, iSCSI, SCP, SNMP, SSH, TCP, and other data and management protocols. Your array might differ from the one shown. . The below requirements are needed on the host that executes this module. A network configuration enables a Nimble Storage array to be accessed and managed from the network, communicate with other arrays in a group, carry data traffic, and replicate volumes. The parameters can be applied using the nimble. Click Make Active in the dialog box to confirm that you want to activate the selected network configuration profile. You assign network settings to one of three network configuration profiles: Active, Backup, and Draft. This document deals with procedures to manage the array and to automate common tasks using the array OS command line interface (CLI). By default, authentication is enabled after you join the domain. Jun 7, 2021 · HPE Nimble Storage dHCI now makes network deployment and configuration radically simple, enabling organizations to increase productivity and operational efficiency. If you make any changes on the Active Directory server that are related to the Active Directory configuration on the array, you might need to disable Active Directory authentication and re-enable it to clean up the cache. 1. ; On the General panel, click Configure Draft Settings. Create a Draft Network Configuration Profile; Activate a Network Configuration Profile; Delete a Draft Network Configuration Profile; IP Addresses. 9 or later. Ensure that the iSCSI initiator on the vSphere host (s) is enabled. View Backup Settings. The basic format of a nmcli command is as follows: nmcli [OPTIONS] OBJECT { COMMAND | help } where OBJECT can be one of the following options: general, networking, radio, connection, device, agent, and monitor. From here we can also configure a new technology Nimble call “Virtual Target IP addresses” as well as creating “Network Zones” to stop • Task 1: Launch HPE Nimble graphical user interface (GUI) • Task 2: Review network configuration • Task3: HPE Nimble array administration • Task 4: Configuring and starting a Syslog server and SNMP Trap Receiver • Task 5: Creating and connecting to a volume • Task 6: Connect the server to the HPE Nimble Storage volume Configure Custom Log Locations. An upgrade procedure is the same as replacing a controller or the cache SSDs. x arrays. Note: If you choose the Custom frame size, you must specify the size in the Bytes field. Choose either: Click Revert to make the Backup configuration the new Active profile. Note: The iSCSI host-to-array connection process is faster and simpler when you install and use Nimble Connection Procedure. Select Manage > Data Protection , then click Replication Partners in the left pane. ; Click Delete. 1200 W power supply (Delta DTQ1201AN12F11) AC input voltage: 100-120V or 200-240V. From the dropdown menu ( ), choose Settings. Keep in mind that these are basic examples and overviews. Network Configuration Profiles. 0 or later. Sample network configuration using two VMkernel ports and a single vSwitch To prevent a single-switch failure that might cause a virtual infrastructure outage, HPE recommends that you use dual physical switches for the connection between the ESXi host and the HPE Nimble Storage array. Modify settings on the Group, Subnets, Interfaces, and Diagnostics tabs. Head back to the Nimble Storage GUI and paste it into the Initiator Name. 55 --netconfig draft --type management --newaddr 192. Subnet Traffic Types; Subnet Traffic Assignments; IP Address Zones in Subnets; Configure a Subnet; Delete a Initial configuration and set-up can be completed in less than two hours. x and later and using the Automatic iSCSI Connection Method under Network Configuration Group One Shared Network In this configuration, the management and data traffic share the same physical network interfaces. Ethernet connectivity to the HPE Nimble Storage a rray supports this continuous access by enabling redundant network connectivity and flexible architecture. 0 and Later Next topic : Server, Array, and Switch Cabling Example Configure Firewall Ports. You can delete an existing Draft network configuration profile. IP address: Enter an IP address on the management network. Manage the storage network configuration on the HPE Nimble Storage group. 6. Editing a management IP addresses using the Draft network configuration profile: Nimble OS $ netconfig --create_draft_from active Nimble OS $ ip --edit 192. Click Add to add a new replication partner. Aug 28, 2023 · It is a way to integrate network configuration instead of managing network connections manually. I now have a new initiator group with one initiator in it. Aug 17, 2016 · Configuring Nimble Storage array inside the Veeam console is easy and intuitive. Clusters can be scaled to 32 compute nodes either at the time of setup (Setup automation software) (or) can be expanded at a later time using the Nimble dHCI vCenter plugin. Sep 6, 2019 · Step by step video tutorial on how to setup a HPE Nimble array using a mixture of CLI and GUI. 92 Choose Administration > Network . Network devices are the crucial components of the enterprise and unauthorized configuration changes could wreak havoc on the network. The checks it does range from somewhat common, to very in-depth checks. CLI A network configuration enables a Nimble Storage array to be accessed and managed from the network, communicate with other arrays in a group, carry data traffic, and replicate volumes. If you want to manage your array using the GUI, refer to the GUI Administration Guide. Select Nimble Studio File Transfer from the list. Use the name 'draft' when creating a draft configuration. username (True, str, None) HPE Nimble Storage user name. g. is rm cb cw vp wo hy ba rh lo