Dixell digital controller manual pdf. It provides three digital (relay) outputs, one for the compressor and the other ones to control the fans. It has four relay outputs to control. 10. 2 PRECAUCIONES DE SEGURIDAD Verifique que el voltaje de alimentación sea el correcto antes de conectar el instrumento. Model XRi77CX, format 32x74mm, is microprocessor based controller, suitable for applications on. In case of long-distance sensor installation from the controller, the sensor cable may be prolonged up to 100 m max. The controller is fully configurable through spe-cial parameters that can be easily programmed through the keyboard. Model XR70CX, format 32 x 74 mm, is microprocessor based controller, suitable for applications on. It has 4 relay outputs to control compressor, fan, defrost, which can be either electrical or reverse cycle (hot gas) and light (configurable). - To connect (by wire) all digital inputs set as ixF=dEF A maximum number of 20 controllers can be used in this configuration. and 2, which can be either electrical or reverse cycle (hot gas). Digital controller for CDU management. times, the regulation is locked and a manual restart is required. It is provided with 3 relay outputs to control compressor, defrost - which can be either electrical or hot gas - and the evaporator fans. XR03CX. port RS485. It provides a relay output and a PTC or NTC probe input. 1 HOW TO PROGRAM A HOT KEY FROM THE INSTRUMENT (UPLOAD) Program one controller with the front keypad. 1. In this case the relay 1-3 can be activated only by digital input with i1F or i2F = AUS. The HOT KEY receptacle allows programming the controller by means the HOT KEY programming keyboard. 3. Page 1 XR75CX Digital Controller for Medium-Low Temperature Refrigeration Applications Installation and Operation Manual 026-1210 Rev 4 Page 3 Emerson 1065 Big Shanty Road NW, Suite 100 Kennesaw, GA 30144 USA 770-425-2724 • www. Digital Controller. Page 1 2. 6. DIGITAL CONTROLLER. Models XR20C, format 32 x 74 mm, and XR20D, DIN rail format, are thermostats with off cycle defrost designed for refrigeration applications at normal temperature. Dixell controller pdf manual download. · Do not expose to water or moisture: use the controller only within the operating limits avoiding sudden Dixell technology is leading the way in electronic regulation and control in the fields of refrigeration, air conditioning and heating, and retail. Opcionalmente, la entrada digital puede convertirse en una tercera entrada de sonda. It is also. The device is also provided with up to 4 NTC, GENERAL DESCRIPTION. page of 3. Summary of Contents for Emerson Dixell XR75CX Series. 1 PLEASE READ BEFORE USING THIS MANUAL • This manual is part of the product and should be kept near the instrument for easy and quick reference. Do not expose to water or moisture: use the controller only within the operating limits avoiding 10 ELECTRICAL CONNECTIONS. “End”. In case of failure or faulty operation send the instrument back to the distributor or to “Dixell S. modelo XR75CX, formato 32 x 74 mm, é um termostato digital para aplicações ventiladas em refrigeração em medias e baixas temperaturas. La salida HOT KEY permite conectar la unidad, por medio del módulo externo XJ485-CX, a una red compatible ModBUS-RTU tal como las unidades de monitoreo Dixell de la familia X-WEB y permite programar el controlador a través del teclado de programación "Hot Key". A. gas). Enter the programming menu by pressing the SET+ n for 3s. IMPORTANT: Your unit is preprogrammed. can be either electrical or hot gas - the evaporator fans and the lights. It allows to program the controller by means the HOT KEY programming keyboard. NOTE: the cycles (ES → Standard mode → ES …. Two Stages Digital Controllers with Multi Probe Input 1. Push “SET” key and the End will stop flashing. Model XW260K is microprocessor based controller suitable for applications on medium or low temperature. GENERAL WARNING. GENERAL WARNING 1. Heat-resistant cables have to be used. XR70C– XR70D – XR72C. 1 CONTENTS. Dixell Srl se réserve le droit de varier la composition de ses produits, sans le communiquer au client, tout en garantissant toutefois le fonctionnement identique et inchangé des produits. SYd=nSY. The XM670/XM679 controllers come with a screw terminal block to connect cables with a cross section up to 1. + 1. Installing and operating instructions. Turn OFF the instrument remove the “Hot Key”, then turn it ON again. compressor, fan, defrost, which can be either electrical or reverse cycle (hot gas) and light. It provides a relay output to drive the. This manual is also suitable for: Dixell xc30cx Xc30cx. Model XR60CH, format 32 x 74 mm, is microprocessor based controller, suitable for applications on. Model XR10C, format 32 x 74 mm format is a single stage temperature controller suitable for. The same recommendations apply to probes. Model XR40C, 32x74 mm format, is a microprocessor based controller, suitable. ) are always operating with iF or 2F=do and Et and St different from zero. Digital controller with defrost and fans management. IDPlus 961 -HC IDPlus 974 -HC KEYS UP Press and release. refrigerating units. This manual is also suitable for: View and Download dixell XR06CX instruction manual online. Model XW60L, format 38x185mm, is microprocessor based controller, suitable for applications on medium or low temperature ventilated refrigerating units. XR06CX control panel pdf manual download. Model XR44CH, format 32 x 74 mm, is microprocessor based controller, suitable for applications on. The Dixell Universal Replacement Controller has three Voltage options … 12/24 Vac/dc, 120Vac, and 230Vac. They provide two relay outputs, one for the compressor, the other one can be used for alarm signalling or as auxiliary output. Turn on power, THEN WITHIN 1 MINUTE COMPLETE STEPS 3, 4 AND 5. 22 MB. 1 CHECK THE SW REL. quick reference. compressor 1, compressor 2, fan and defrost, which can be either electrical or reverse cycle (hot. XW03K is provided with Minifit 2, 2 poles, for probes and the keyboard, JST 2 poles for digital input. (+66) 02 017 6900 (24 hrs) Mobile. It is also provided with 3 NTC or PTC probe 2. The HOT KEY output allows to connect the unit, by means of the external module XJ485-CX, to a network line ModBUS-RTU compatible such as the Dixell monitoring units of X-WEB family. Model XR30CX, format 32 x 74 mm, is a digital thermostat with off cycle defrost designed for The “Lo” message will be displayed followed by the minimum temperature recorded. HPF Minimum time of compressor off when the HP digital input is activated (0 to 15 min). It must be connected by means of a two-wire cable (∅ 1mm) at a distance of up to 30. on medium or low temperature ventilated refrigeration units. After any defrost request (received by RTC, timed by par. 5 simple steps. idF1 parameter sets the defrost (see address) with a detailed description of the fault. If the SW release is 5. medium or low temperature ventilated refrigerating units. OF THE CONTROLLER 1. Upper display shows “rSt” label if the alarm can be reset, “NO” label if it is not possible. It is also provided with 2 NTC or PTC probe inputs, the first one for temperature. Models XR10C, format 32 x 74 mm, and XR10D, DIN rail format, are a single stage temperature controllers suitable for applications in the field of refrigeration or heating. XR110C is connectable to the XJ500 monitoring system through the two terminals of serial. When the controller is ON, insert the “Hot key” and push o key; the "uPL" message appears followed a by flashing. NOTE: the HP safety digital input is checked only when the compressor is running If the HP safety digital input is activated, the following actions will be performed a. . reading time 15 minutes. It provides two relay outputs, one for the By pressing the GENERAL DESCRIPTION. GENERAL DESCRIPTION The XM668D and XM678D are high level microprocessor based controllers for Download this manual. Brand: Emerson | Category: Controller | Size: 1. It has 2 relay. Table 1: parameter tC settings 2. XR03CX – XR04CX. lib. USE OF THE PROGRAMMING “HOT KEY “. It acts as a pure transducer controller, receiving a regulatig input from a master controller and transforming it in the relative modulating signal for the digital unloader valve. It has 2 relay outputs to control compressor and defrost, which can be either electrical or reverse cycle (hot gas). 3 ON/OFF RELAY (OAX = ONF) When oAx=onF, the related relay is activated when the controller is turned on and de-activated when 3. View and Download dixell XR570C installing and operating insructions online. 0 inc Integration time 300. It has to be connected by means of a two-wire cable18-24 2. l. Model XR20C, format 32 x 74 mm, is a digital thermostat with off cycle defrost designed for. Disconnectable screw terminal blocks are used for power supply and loads, for cables with a cross section up to 2. - Same defrost start, end defrost independent. It has 2 relay outputs to control compressor and. •Scrolls through menu options •Increases values. Model XC30CX, format 32x74mm, is a digital thermostat for condensing unit applications. refrigeration applications at normal temperature. Digital controller. Just follow these. • The controller should not be used for purposes different from those described in this manual. K20345-C, K20745-C, K21145-C. The device is also provided with 2 NTC probe inputs, the first one for temperature. One of the features that distinguish the iPRO controllers is the vast range of connection options with external devices, Dixell as well as other brands. se reserva el derecho a variar la composición de sus propios productos, sin necesidad de comunicarlo al cliente, garantizando de todas formas su idéntica e invariada función. Go. for applications on medium or low temperature refrigerating units. 5V readout for P2 435 FA04 4mA or 0. Set the kind of probe: a. Model XR30CX, format 32 x 74 mm, is a digital thermostat with off cycle defrost designed for refrigeration applications at normal temperature. emerson. The device is. 4 How to Reset an Alarm Event. With the press of a few buttons, the control can be set up to replace Dixell controls, such as: XR10C, XR10CX, XR110C, XR02CX, XR20C, and CX, XR120C, XR03CX, XR30CX, XR04CX, XR40CX, XR06CX, XR60CX, XR160C and other manufacturer's controls. without any re-calibration. 1 LEIA ANTES DE USAR O MANUAL Este manual é parte do produto e deve ser mantido próximo ao aparelho para consulta rápida e simples. 4. The probe input can be selected between PTC or Models XR60C, format 32 x 74 mm, and XR60D, DIN rail format, are microprocessor based. Model XR01CX, format 32 x 74 x50 mm format is a single stage temperature controller suitable for applications in the field of refrigeration or heating. The temperature range allowed for correct operation is 0 60 °C. El modelo formato XR06CX 32x74x60mm, es un controlador basado en microprocesador apto para aplicaciones en unidades de refrigeración aireadas para media y baja temperatura. Dixell Srl reserves the right to change the composition of its products, even without notice, ensuring the same and unchanged functionality. Model XR60CX, format 32 x 74 mm, is microprocessor based controller, suitable for applications on medium or low temperature ventilated refrigerating units. How We Use Cookies: This website uses cookies so that we can provide you with the best user experience and to deliver advertising messages and offers on the website that are relevant to you. Sep 18, 2011 ยท • Dixell reserves the right to change the composition of its products, even without notice, ensuring the same and unchanged functionality. Program one controller with the front keypad. Dixell XR06CX Operating Manual (3 pages) Digital controller with defrost 2. with built-in RS485. Dixell Asia Service Center. applications in the field of refrigeration or heating. Instrument XR20CH shall be mounted on vertical panel, in a 29x71 mm hole, and fixed using the special bracket supplied. View and Download Glastender Dixell operation manual online. Model XR110C, 32 x 74 mm format, is a single stage temperature controller suitable for. The RS485 serial output allows to connect the unit to a network line ModBUS-RTU compatible such as the Dixell monitoring units of X-WEB family. Model XW60VS, 100x64 format, is microprocessor based controller suitable for applications on medium or low temperature refrigerating units. , NW Suite 100 Kennesaw, GA 30144 USA Phone: 770-425-2724 Fax: 770-425 2. Ordering Code CAUTION! • This manual is part of the product and should be kept near the controller for easy and quick reference. Est. The XR06CX, format 32 x 74 x 60 mm, is microprocessor based controller, suitable for applications on medium or low temperature ventilated refrigerating units. One attached transformer 2. It is also provided with up to three NTC. CANBus, RS485 Master and Slave, and an Ethernet and USB port provide maximum flexibility of integration with the outside world. It has 2 relay outputs to control. To change the Set value push the o or n arrows within 10s. · Dixell Srl reserves the right to change the composition of its products, even without notice, ensuring the same and unchanged functionality. It has three relay outputs to control compressor, fan, and defrost, which can be either electrical or reverse cycle (hot gas). 1 Functioning 5. dixell XC10CX controller pdf manual download. GENERAL DESCRIPTION. - If the controller is in ES and the door is open more than do time, the controller restart standard set point. compressor, fan, and defrost, which can be either electrical or reverse cycle (hot gas). Le XR02CX, format 32x74x50mm, est un régulateur digital avec gestion du dégivrage, destiné aux applications dans le domaine de la réfrigération en température normale. It provides a relay output to drive the compressor. The XEV02D is a slave module designed to be used with a master controller. 1 PLEASE READ BEFORE USING THIS MANUAL. medium or low temperature refrigerating units. The digital input can operate as third temperature probe. Push the SET key for more than 2 seconds to change the Set point value; 2. Typical Connections - for General Guidance Only. Download this manual. Lower display shows the alarm code. Dixell XR06CX Instruction Manual (76 pages) Electronic control instrument/panel. on medium or low temperature ventilated refrigerating units. Está provisto de 3 salidas de relé para el control del compresor, deshielo que puede ser de tipo eléctrico o a inversión de ciclo (gas caliente), y de ventilador. 6 mm2 for all the low voltage connections: the RS485, the LAN, the probes, the digital inputs, and the keyboard. It has three relay outputs to control compressor, fan, and defrost which can be either electrical or reverse cycle (hot gas). Dixell XR60CX Operating Manual. Avoid places subject to strong vibrations, corrosive gases, excessive dirt or humidity. com Label Name Range Default Level Temperature alarms “HA” and “LA” automatically stop as soon as the thermostat temperature returns REGULATION °C/°F to normal values. compressor, fan, and defrost which can be either electrical or reverse cycle (hot gas). dixell XR03CX Installing And Operating Instructions. Advertisement. Controller. To memorise the new set point value push the SET key again or wait 10s. It is also provided with 2 NTC or ratiometric probe inputs, to be used on the suction and condenser line. It is provided with three relay outputs to control compressor, defrost - which can be both electrical or hot gas - and evaporator fans. Accessories for the temperature controller 1. This manual is part of the product and should be kept near the instrument for easy and quick reference. Electrical Control Panels Assembly PLC, SCADA, HMI Building Automation Energy Saving Solutions Installation Services Cold Room Components and Parts Quick Start up Procedure – up and Running in 5 Easy Steps. (+66) 09 5885 4647 (24 hrs) QUICK LINKS. Parameter “Tc” Settings. 4. The value of the set point will be displayed and the "°C" or "°F" LED starts blinking; 3. It is also provided with 1 NTC probe input and one configurable digital input. DESCRIÇÃO GERAL. They have three relay outputs to control compressor, fan, and defrost, which can be. Dedication to technological innovation and constant focus on efficiency have driven the development of solutions designed to maximize energy savings. El modelo XR60CX, formato 32x74 mm, es un controlador basados en microprocesador apto para aplicaciones en unidades de refrigeración para baja temperatura. Contents ____________________________________________________________________________ 1 2. Parameter List. 2 PRÉCAUTIONS Vérifier le bon voltage avant le raccordement de l'appareil. compressor. designed for refrigeration applications at Emerson Dixell XR06CX User Manual. Press and hold for at least 5 seconds. No modo programação, navega-se pelos parâmetros ou aumenta o valor exibido. 2 On/off relay – oA3 = onF In this case the relay is activated when the controller is turned on and deactivated when the - rned off. Model XW260L, 38x185 mm format, is microprocessor based controller suitable for applications on medium or. Look at the SW rel. The temperature controller cannot be installed in the area with water drops. low temperature refrigerating units. Model XR30C, format 32 x 74 mm, and XR30D, DIN rail format, are digital thermostats with off cycle defrost designed for refrigeration applications at normal temperature. either electrical or reverse cycle (hot gas). It cannot be used as a safety device. The XR77CHC, 32x74x60mm format, is a microprocessor-based controller suitable for applications. Controller for temperature: Pt= Pt100, J = J thermocouple, c = K thermocouple, S = S. Installation and Operating Instructions. NOTE: the “Err” message is displayed for failed programming. The instrument shall not be used for purposes different from those described hereunder. 2 GENERAL DESCRIPTION. outputs to control compressor and defrost, which can be either electrical or. 3 Neutral zone regulation With oA3 = db the relay 1-3 can control a heater element to perform a neutral zone action. 2 DESCRIPCION GENERAL. controller, suitable for applications on medium or low temperature ventilated refrigerating. 5. Install the new Universal-R, connect the correct number of probes and connect the wiring See below: 1. reverse cycle (hot gas). Select the Pbc (Probe configuration) parameter and push the SET key. compressor, fans, light and defrost or auxiliary output. Model XR60CX, format 32 x 74 mm, is microprocessor based controller, suitable for applications on. Devices connect via an RS485 network or Wireless options. The data collected from the HVAC/R systems can be viewed and remotely controlled online. It can work with PTC or NTC probes. Model Universal-R is a 71x29 mm format microprocessor based controller, suitable for applications on high, medium or low temperature refrigeration units. Model XR02CX, format 32 x 74 x 50 mm, is a digital thermostat with off cycle defrost designed for. Push and release the “SET” key the lower display shows the alarm code. Also See for XR60CX: Installation and operating instructions manual (18 pages) , Installing and operating instructions (5 pages) 1. Press the “DOWN” key for 3 seconds and the controller will automatically 13. It has four relay outputs to control compressor 1 and 2, defrost 1. Two temperature sensors 3. They have a relay output to drive the compressor and a PTC or NTC probe input. This manual is part of the product and should be kept near the instrument for easy and. It is provided with four relay outputs to control compressor, defrost - which. It's provided with a relay output and a. GENERAL DESCRIPTION The XM669K and XM679K are high level microprocessor based controllers for The XR06CH, format 32 x 74 x 60 mm, is microprocessor based controller, suitable for applications. Brand: Dixell | Category: Control Panel | Size: 6. XR570C thermostat pdf manual download. Model XW60LH, format 38x185mm, is microprocessor based controller, suitable for applications on. 3. Enter the function “menu”. USER INTERFACE. dixell Manuals. 0 Pbd Control band compressors 10 PNU Unit of pressure measurement PSI CF Temperature unit °F dEU Select type size parameters of temperature or pressure Pr4 FCAL P2 Offset 0 FA20 20mA or 4. dixell XR60CX Installing And Operating Instructions. Model XR70CX, format 32 x 74 mm, is microprocessor based controller, suitable for applications on medium or low temperature ventilated refrigerating units. idF, manually by defrost button or by digital input set as dEF), all controllers will load a random Le régulateur est entièrement configurable grâce à ses paramètres facilement programmables à partir du clavier ou grâce à la Hot Key. •Function can be configured by the user (see parameter H31) •Manual defrost function enabled (H31=1) by default. i1F, i2F=AUS the AUX relay is switched on and off by digital inputs. Model XR72CX, format 32 x 74 mm, is microprocessor based controller, suitable for applications on. units. 2. 0 - cod. compressor and fan. 1 How to set the probe. p. It has 4 relay outputs to control. or the display. View and Download dixell Wing Series installing and operating instructions online. Page 1 026-1203 Rev 3 03-FEB-2015 XR35CX Digital Controller for Medium Temperature Refrigeration Applications Installation and Operation Manual Page 3 Emerson Climate Technologies Retail Solutions 1065 Big Shanty Rd. Dixell S. GENERAL DESCRIPTION Press and release the n key. r. 2 GENERAL DESCRIPTION Model XW60K is microprocessor based controller suitable for applications on medium or low temperature refrigerating units. Model XW60LH, format 38x185mm, is microprocessor based controller, suitable for applications on medium or low temperature ventilated refrigerating units. -oAx cut in = SET-HY Iniciar degelo manual. 5V readout for P2 0 P2C Presence probe 2. provided with 2 NTC probe input. Ne pas exposer l'appareil à l'eau ou à l'humidité. Summary of Contents for Emerson Dixell XR35CX - 110VAC. The De-Synchronized defrost mode is enabled by par. A internal timer manages the off cycle defrost. • The instrument shall not be used for purposes different from those described hereunder. Other inputs, power supply, and relay connections are provided with a Faston connection (5. Also for: Wing xw10l, Wing xw10v. A digital input can be set to operate as fourth temperature probe. It has three relay outputs to control. It is also provided with three NTC or. ” The defrost of the 2 sections of controller starts at the same time. Está provisto de 3 salidas de relé para el control del compresor, del deshielo que puede ser de tipo eléctrico o a inversión de ciclo (gas Model XR70CH, format 32x74mm, is microprocessor based controller, suitable for applications on. Also for: Dixell xc30cx, Xc30cx. Place your unit in the desired location. Dixell parametric controllers, fan speed Emerson dixell XW60K Installation And Operating Instructions Manual. Also for: Xr70cx, Xw60k. It is also provided with three NTC or PTC probe inputs, the inductive loads could be useful. The XR03CX, format 32 x 74 x 60 mm, is microprocessor based controller, suitable for applications. 1. defrost, which can be either electrical or reverse cycle (hot gas). . of XM678D printed on the label of the controller. Wing Series controller pdf manual download. Parameter Table and Factory Default Settings. 0 mm). 2 SAFETY PRECAUTIONS Check the supply voltage is correct before connecting the instrument. This manual contains: set-up instructions, unit specs, safety information, controller operation and maintenance steps. 5. O aparelho possui quatro relês de saída para controle do compressor, ventilador, degelo (que pode ser elétrico ou gás quente) e luz (configurável). Thank you for your purchase. Page 2: Parameter List 2. Model XR40CX, format 32 x 74 mm, is microprocessor based controller, suitable for applications on medium or low temperature refrigerating units. 1592009261 1. The last one. tdS Cycle time for the Copeland digital compressor 20. 4 proceed with this manual otherwise contact Dixell to get the right manual. Table 2: Typical connections. Bookmarks. RECOMENDAÇÕES. SAFETY PRECAUTIONS · Check the supply voltage is correct before connecting the instrument. 2. It provides two relay outputs, one for the compressor, the other one can be used as light, for alarm signalling or as auxiliary output. Page 2 Di x ell Installing and Operating Instructions rel. It has four relay outputs to control compressor, fan, and defrost, which can be either electrical or reverse cycle (hot gas). It has 4 relay outputs to control compressor, fan, defrost, which can be either electrical or reverse cycle (hot gas) and a fourth configurable output. FT1) in parallel with inductive loads could be useful. When the controller is ON, insert the “Hot key” o key; the appears followed a by flashing “End”. meters to the keyboard T620. View and Download Emerson Dixell XC10CX installing and operating instructions online. No modo programação, navega-se pelos parâmetros ou diminui o valor exibido. 5 mm2. Tel. With Et or St=0 the controller doesn’t change the operating mode, and it’s possible to pass from the The Dixell XWEB300D is a web server that is connected to Dixell probe acquisition modules and/or Dixell digital controllers for a distributed control system. Enter the Programming mode by pressing the Set and DOWN key for few dtE Defrost termination temperature: (-50,0÷110,0°C; -58÷230°F) (Enabled only when the evaporator probe is present) sets the temperature measured by the evaporator probe which causes the end Digital controller with defrost and fans management (4 pages) Summary of Contents for dixell XR20C Page 1 To see the kind of alarm, the max (min) reached temperature and alarm duration do as follows: Model XR20C, format 32 x 74 mm, is a digital termostat with off cycle defrost Push the Up or Down key. 4 NEUTRAL ZONE REGULATION With oAx=db the related relay can control a heater element to perform a neutral zone action. Electronic control instrument/panel. It cannot be used as a safety Model XR40CX, format 32 x 74 mm, is microprocessor based controller, suitable for applications on. of the controller printed on the label of the controller. Use o or n keys to find the “ALrM” label. 13 MB. oq rv mm bb jm ac nc yg ht zk