Antminer s9 disable fan check Used to hold the hash board from external impact, better data transmission with the control board, and mining bitcoin. BITMAN. (google the manufacturer name on the fan itself to find this info) then find a fan on amazon or ebay that Product description: Frame case for Antminer S9 The case frame kit is made of aluminum and is suitable for the case of the BTC miner Antminer S9. News: Latest will disable freq setting. Is there any way to solve this problem or must the miner be repaired by bitmain? "bitmain-fan-ctrl" is the parameter that determines whether or not your fans are controlled automatically or manually. The sound should sound like metal literally bouncing around unevenly. I've used the tuner to turn the idle speed down to 2400rpm and the noise is very livable. check the interface or log can detect the fan Fan number, you can locate which fan is not working, check whether the fan and the appearance of the connection line is physically damaged, if damaged, replace the fan. This is a Sample I've been using antminer s9 with noctua fans as space heaters for 2 years and I can confirm it will work. Turn off you need bypass oem fans first and after connect silent fans to spin full blast. The fan is a Delta QFR1212GHE-SP01, and it can be purchased from Digikey. There is a way to control the fans on the S9e, apparently, Bitmain made it a little bit harder to do than it was on the older S9 versions, I however and by chance managed to find a way to do so. Antminer S21, T21; Antminer S19, T19; opportunity to disable the timer (stage 3) in profile was added; fans checking was carried out and the limit for 500-800 rpm was added(it happened that the back fan was disabled, but it was rotating due to the stream from These fans are designed to significantly reduce noise through advanced blade designs, noise dampening features, and lower RPMs. Setting up the Antminer S9 is relatively straightforward, even for those who are new to mining. #takeminingback. . For Official Foundry support, join the Discord (link below). I have 1 1000watt psu 7) Made a check of fans, and added a limit of 500-800 rpm (the situation when the rear fan is dead, but rotates due to the flow from the front at the minimum speed) 8) Redesigned output information when immersion mode turned on. One of the hash board's temperatures exceeds 80°C. 2 for Antminer S9 or higher built on 2020-12-04 14:30:01 UTC Wed May 5 03:05:58 2021 daemon. 1. Remove the cover of your Antminer S9 and inspect the control board for physical damage. Locked post. Unscrew: Remove the screws or clips holding the fans in place. At 13. Switch Mining Pools. Reviewed in France on June 3, 2020. Troubleshooting steps: 1. 0 out of 5 stars 1 4 offers from $37995 $ 379 95 No 2 Fan find, check againfan-num 2 fan-map 12 请问这是什么原因造成的? ANTMINER Troubleshooting & Repairing/蚂蚁矿机故障诊断与维修; Antminer Z15 No 2 Fan find, check again Follow. Click to find the best Results for antminer s9 fan silencer Models for your 3D Printer. Disable reboot after X times: This Remove. Hi guys! Friend of mine gave me his old Antminer S9's (5 of them) to keep. 4. That in turn = loud. Andrew Disable fan check. Our aluminum heatsinks are specially designed for Bitcoin mining cooling systems, are especially for miners S7 S9 M3 V9 D3 A3 T9+ series. Sign In Upload. Ensure all components are present and undamaged. Bitcoin Forum: January 14, 2025, 10:22:48 PM: Welcome, the software understands that the tachometer has shorted, and will stop mining if either fan has the 30600 rpm speed. It is compatible with Antminer V9, S9, S9J, S9K, S9SE, S11, S15, S17, S17Pro, S17+, T17, T17E, S19, and S19Pro ASIC miners. ,A few are due to the operating environment, fans, external network, firmware and so on Hello, I live in an old 1930's NYC apartment with old wiring. Bitmain Antminer S9 Troubleshooting of various Bottom row 12 The order in which the voltage domains are arranged in turn:CLK、CO(TX)、RI(RX)、BO 、RST. Actually, I think it might need to be even larger Hi I also unpacked a brand new antminer s9 yesterday, 1 hashboard not showing. FREE delivery 21 - 23 Jan. The S9 uses two of those. If you do not connect to the control board, and go straight to the hashboards, the fans will not turn on to cool your machine and it may catch on fire. Antminer About. one 140mm 3000rpm with 3d printet adapter on the front, and no fan on the back and no back stop/fan mount bracket. X. El ventilador se puede utilizar para la instalación en el chasis, y el motor del ordenador es muy estable. Seven common fault phenomena and solutions in the log. Hi, I would like to ask you if anyone tried to use the Fan simulator to eliminate the original loud fans. achète pour remplacer un ventilo cassé sur un antminer. Used to fix the hash board and control board, and connect the cooling fan. This type of failure is mostly caused by an operational board failure. main. Then I flashed it with the SD card method, let it run for 30 min after with 2 reboots. The fan check should be turned off when using immersive cooling Hey guys, decided to make a video showing how to modify the firmware for the antminer S9. vi bmminer. Bitcoin Miner Machine Antminer S19 Pro,Professional Bitcoin Miner Crypto Miners Supplie,Bitmain Asic Miner BTC Bitcoin Mining Machine. (2) If the fan is damaged, replace the damaged fan directly. Also for: Antminer s9. Please check the plug of two fans Or find a normal fan to replace it. Overclocking up to 19 TH / s on air cooling. Dual Ball Bearings High Speed Durable Mini 4Pin DC 12V 2. Bitcoin Forum: June 18, 2024, 04:35:03 PM : Welcome, Guest. Stop Using BITMAIN Machines, Firmware LESS Antminer L3+ Scrypt Litecoin Miner, 504Mh/S Hashrate ASIC Miner, LTC Doge Coin Mining Machine Better Than Antminer L3 S9 S9i 5. When the miner's alarm is in batches, please check whether the phenomenon in this document is the same as the Personally I’m under-volting mine to 8v in order to reduce temperatures and constantly be able to run the fans at 50% at 10TH/s with fresh air intake and every time I start the miner the fans go to full speed as a precaution, if you Problem Antminer s9 : Fatal Error: some Fan lost or Fan speed low! Bitcoin Forum: January 14, 2025, 12:14:54 PM: Welcome, Guest. running 2 of these on an Antminer S9. It only came with 1 fan, i ordered the new fan but ill be a while. Antminer S9 fan specifications. 5Th/s. 8) We did a fan check and added a 500-800 rpm limit (a situation when the rear fan is dead, but rotates due to the flow from the front at the minimum speed). (thread here The fan is also very noisy, so after a few days, I replaced the stock fan with a quieter Noctua NF-A6x25 60MM FLX SSO and a CRJ 3-pin computer fan to 2-pin PSU adapter. Problem 4: Network Connectivity ANTMINER S9/S7/L3 MUFFLERS Fan Noise Reduction ADVERTISING: Disable your banner blocker (AdBlock, ) and click on our banner ads. Without changing the software (firmware). conf You are now in the vi editor, you should see the entire contents of the bmminer. 14. I have a small spare bedroom that I was thinking about putting an Antminer S9 in to mine Bitcoin. conf file on your There are some config options for fans, but the fan check offers only 1 or 2 fans to operate. - Exclude all three cards from power supple, and turn on with the controller card. By So, here's the "fix": I tried switching the fans with L3+ miner and with those S9 boots just fine. Replace the Fans: The fans in the Antminer S9 are crucial for keeping the machine cool. Sleep Mode: Mining can stop and fans ANTMINER E9 Pro; See more ANTMINER S9 Hydro Created August 30, 2018 03:17; Updated February 15, Fan speed low or not spinning > How to drain S9-hydro > All other technical questions > Repair my S9 Hi, I just made some binaries for our Antminers S9. Fan is variable speed which is nice, allows you to throttle up or down. DUDUGUAI. If you turn them on I'd go for LPEM to get the best bang for your buck. This arduino code allows you to control the fan speed of an antminer s9 without causing alerts on the miner. X or 0. These Miner Type Antminer S9 Hostname antMiner Model GNU/Linux Hardware Version (I think this said 2. It works also with R4. Remove the hash boards from the case and add external quiet fans to reduce noise. Introducing an innovative system designed to significantly minimize the noise generated by the Antminer S9, this solution empowers users to seamlessly integrate a larger blower for enhanced performance. Share Sort by: Best. Setting Up the Antminer Bitmain S9. 5. PSUs with quieter cooling systems, such as those equipped with larger fans or fanless designs, can help minimize noise disturbance. Supports popular ASICs: Support for all Antminer S17/T17,S9/S9i/S9j models. ASIC Mining. Read more. 1 mskminer. Asicboost technology. Port Remove Error signature antminer s9 s9i s9j t9plus firmware 2019for buy file https://t. Some credit to u/qwerty4ever for getting me started in the right direction, I've learned a lot about Linux on this adventure!. Id rather not order from bitmain because of the wait time, I need something here within the week. Download Table of Contents Contents. Add to my manuals. All AntMiner S9s are tested and configured prior to shipping to ensure easy set up. Este producto tiene un ventilador desmontable que puede funcionar con un regulador de voltaje. Fan RPM check: Enabled by default. Doesn’t really bother me as id rather them not be running on high 24/7. This unit is 390 cfm. By Silent Running AntMiner L3+In this video you guys wanted me to show you how you could make a Antminer L3+ run quietly well here it is I can hardly even notic Wed May 5 03:05:58 2021 daemon. With the intake being a little hidden on the left side on ceiling. When the miner is powered on, the miner's fan does not turn, and the network port light does not light up. Yup, roughly the same settings here too but with power limit at 1420W. 12, 0. Check the system with a measuring device for the absence of OC AsicBoost Antminer S9, T9+ Bmminer - Deploy Tool and access to set freq, volt, Fan Disable . Rated Voltage: DC 12V; Rated Current: 2. ASIC Miner인 antminer S9의 cooling fan 소음이 커서 불편함을 많이 느꼈습니다. Remember that Antminer S9e has a max PCB temperature of 85 as labeled by Bitmain,and it will stop hashing at 80, so reducing the fans speed might How to Soundproof and cool Antminer s9 using just a custom fan shroud steemit. Where can I order proper replacement fans for the S9, intake and exhaust as they run at different speeds. c:12571:bitmain_c5_init: Checking fans driver-btm-c5. 9. 그래서 fan 소음을 줄이는 방법을 연구하기 시작했으며 이제 방 안에서도 If you need to repair Antminer S9k S9se, in addition to the necessary tools mentioned above, you also need Universal test fixture, 862D desoldering station, Tin scraper and other efficient tools. Firmware for Antminer S17, S17pro, S17+, S17e, T17, T17e, S9, S9i, S9j, S9k, S9se, T9+, L3+, L3++) Figuring I can cut and solder the fan connector, I really need to find a fan. Really, how do you do that? (1) Reconnect the fan, check the number of fans that can be detected, accurately locate the fan that is not working properly, and then replace the fan. Plug the fan simulator into the front fan socket. Fan Error The general Antminer failure problems mainly include: unable to find the IP of the miner, inability to power on the miner, low hash rate of the miner, and no hash rate. Here’s a quick guide to get you started: Unboxing: Upon receiving the Antminer S9, you’ll find the unit itself, along with a power supply unit (PSU). In my case there were 2 of 3 hashboards dead on my T9+. 2 dBA This article mainly explains the possible problems and solutions of Antminer S7, Antminer S9 (fixed-frequency) & Antminer L3+. Open comment sort options I really wish people would stop posting any and everything that has smaller than 5" shroud/ducting/venting. I run a little above mid throttle. (2) If the problem still exists after replacing the fan, the control board is Fan emulators, tricks, Fan Emulator - all these names are one device. Note: Add # to the first 15 lines and remove # from the following 5 lines Adding # means that the line is commented and won't be Awesome Miner Antminer firmware S9/S17 - Configuration. Release 3. - Exclude from power supply two of three cards, issue continues. Ignore scammers on Skype, Telegram, etc. Which is used to disable / emulate the operation of the ASIC miner's fans when immersed in a dielectric fluid. If you flash the miner with the latest firmware and you trying to downgrade them back it won't work because 2019 firmware has new security they also disable your SSH access with this firmware. Fan shroud: Fan and PSU shroud: It can remove the heat and noise generated by the power supply and fan heat dissipation from the room. Running 4" is not enough for the airflow of the fans Topic: Antminer L3+/S9 without fans. Download. More posts you may Antminer (S17. Stop buying industrial miners, running them at home, and then complaining about the noise. Currently, the default firmware on the S9 is blocking me from being able to test these alternate cooling setups -- if it doesn' detect the fan tach signal it just stops mining. Regularly clean the PSU and Antminer S9 to prevent dust buildup, as it can The key point to remember with s9's is that the fans have to work against a fairly high airflow resistance cause by BM's insane mass of small heat sinks. 0 out of 5 stars conforme. 2. DOWNLOADS. It might work with T9, but I didn't test it. I decided to compile bmminer from official bmminer GitHub repository and since I am no programmer, I am unable to pass per-board parameters, so all binaries have fixed voltage for all chains, it requires only one fan and 3000 RPM max is Topic: Please Help , Antminer s9 only turns on the fan when plugged (Read 277 times) magu99 (OP) Newbie Offline Activity: 6 I've tried the s9 with another PSU and the same thing happens, only the fans turn on, the control board and hashing boards are still off, so it's NOT THE PSU, I think it might be the Control Board. Of course, this choice may be more troublesome, you can also choose the convenient Bitmain Antminer hash board repair bundle . I had another set that didn’t turn on at ALL. 6500 RPM Fan for AntMiner D3/L3+/S9/T9/S7/X3/Z9 AsicMiner Nidec UltraFlo V12E12BS1B5-07. com опции Wachdog ниже Disable chain if it has less than 63 chips and hashrate is below given number of percents Fan and temperature Disable fan check (immersion cooling only!!!) - Отключение проверки вентиляторов (1) Reconnect the fan, check the number of fans that can be detected, accurately locate the fan that is not working properly, and then replace the fan. 9. New comments cannot be posted. Report. "bitmain-fan-pwm" is the parameter that determines your fan speed on a percent scale. 28, 0. Do this at your own risk! I'm very new to bitcoin mining, this is my first miner, an Antminer S9 14TH/s version, and I was getting very annoyed with the fans constantly going up and down, hours of research led me to the following solution. My Antminer S9 just stop mining, and is in a loop of fan start / stop , and never ends out that loop. Verified Purchase. Page 5: Antminer S9 Components AntMiner S9 Installation Guide 1. 6) There is Hey guys are you asking good questions, my take on this is removing the fans completely makes more sense, and our new model which you can see in the videos is not making use of either body or fans, and the stability and cooling ability has increased substantially over the older model, so my advice would be to not go through the motions with the fans or breaking off blades etc, but In comparison, other models like the Antminer S9, which is designed for Bitcoin mining using the SHA-256 algorithm, might offer higher hash rates but also come with increased noise levels and power consumption. Miner locator feature (flashes red LED to locate) Our custom overclock firmware for the Antminer S9, T9, L3, S17, T17, S19 & T19 Series allows overclocking beyond factory limitations. Hope this helps someone. Issue: A large number of Antpools surfaced. Solution: Remove the hash board that exceeds 80℃ for maintenance. Replacement fan for AntMiner DR3 L3+ S9 S9i S9J S9 SE S11 T15 S15 Z11 S17+ S17 Pro S17e T19 S19 S19J Pro DR5 D7 Z9 AsicMiner Nidec UltraFlo Does not turn fan. Every Day new 3D Models from all over the World. Remove: Take out the old fans, being careful not to damage any wires 3) If you need to disable the fan control and remove the fans you must enable the Fan RPM check : fan check turn off (only for immersion cooling) 4) If you want to enable hashrate control function you need to set the value at which the firmware will reload the ASIC if the chains does not show the required hashrate, Restart if Antminer noise reduction ideas. Mount the adapter to the chassis first, Hi, im having the same issue with an s9i i got from a friend. Use the following steps to set the fan speed manually. Please login or register. Topic: How to check the temperature of my antminer s9 (Read 267 times) aryangarg1000 (OP) Newbie Offline Activity: 13 Merit: 0. There are lots of knowledgeable people on Bitcointalk, and I found a conversation thread that helped figure out the part number of the Antminer 6000 RPM fan. Sometimes, mining pool issues cause hashrate inconsistencies. Overclocking up to 22 TH/s immersion cooling. @btcurrencies. Reason: One of the fans is not detected. A couple of things: Noctua fans on all my s9's. Network Configuration: Confirm that your network settings are correctly configured for your Antminer. I What type of fans are these? I would like to swap out the fan for less noise but not lose any hash rate. Near the faulty fan cut the yellow wire and bare the end that goes to the plug. Miner will work well only when both fans are detected. Topic: antMiner S9 fan failure (Read 318 times) Asathelumberjack (OP) Newbie Offline Activity: 1 Merit: 0. 9) Redesigned the output of information when turned on. c:3006:check_fan_beforeInit: get fan[4] speed=5280 The Antminer S9 is a powerful and efficient crypto-mining rig that was first released in 2016. I'm guessing bearing ball got busted, so I'm getting a new fan now. 00. 8-10 TH 85c temp Reply reply Top 33% Rank by size . Few other items. Ix Tech made an useful 3D-printed My idea is to take away the S9 chasis and fans, then submerge the hashboards in mineral oil and place them in a mini fridge. I will only ever contact you via forum PMs. Fault: When the miner is powered on, the miner's fan does not turn, and the network portlight does not turn on. 7A 6000 RPM Cooling Fan Brushless Replacement Case Fan for Antminer Bitmain S7 S9 D3 L3 E9 T9 etc All BTC Miner Server (2. Issue: Miners have no hash rate. c:9103: Chain[6] has core num in PIC It won't stop mining at 80c, not even at 100c, or at least this is what the default firmware allowes you to go to, since S9 has a max temp of 135c 80c is pretty cool, and i have seen those S9 run above 100c for a very long time without a hitch, now going 200c is a different story, I believe that some of these custom firmware have an option to disable the fan-check function in cgminer As far as I understand its only temporary while it reconfigures itself to your settings. You can see it pretty clearly here Help with Antminer S9 IP . January 27, 2017, 09:29:58 PM Stop buying industrial miners, running them at home, and then complaining about the noise. Like a 2fans/hash board Hi, just wanted to let you guys know that after changing the firmware with this procedure, the mac address of the network adapter on controller changed, so if you were configuring the network ip with a DHCP reservation you have to Product description: Bitmain Antminer S9 Control Board Parts Bundle ZEUS MINING has sorted out some waering parts of the Bitmain Antminer S9 control board with professional maintenance knowledge, so as to facilitate Topic: Antminer S9 cross flow fan mod (Read 422 times) coinraiser (OP) Newbie Offline Stop buying industrial miners, running them at home, and then complaining about the noise. If I turn my exhaust fan on full time it stops. About this item Professional mining cooling fan for Antminer S19,S17+,T17,S9 and S19J miner. Busted fan on L3 only reads 640RPM and is unusually warm to touch. Topic: Antminer S9 - Actual CFM at full fan RPM (Read 7374 times) VentMine (OP) Full Member Offline Activity: 236 Merit: 105. Please if anyone has In this tutorial we will convert an Antminer S9 (ASIC Miner) by Bitmain into a silent Bitcoin Heater (Air Heater). Add to cart Couldn't load pickup availability. check whether the control board connected to the fan port is damaged, if damaged, the control board can be replaced or Antminer S1 S3 S5 S7 S9 T9 D3 L3+ Fan Duct Cooling Shroud to 6 Inch Vent Remove the metal fan grills if you don't have any small animals or debris that could get in your miner's fan (judgement call on removing the grills - they cause turbulence and noise, but also protect your fan blades from being broken if something sucks in) ANTMINER S9/S7/L3 MUFFLERS Fan Noise Reduction ADVERTISING: Disable your banner blocker (AdBlock, ) and click on our banner ads. Clean dust from fans and heat sinks to improve cooling efficiency. Antminer L3+ Silent Operation Fan Duct I’m looking for some advice on how to best configure S9’s running Braiins OS+ for optimal energy efficiency. Vnish firmware for Antminer S9, T9+ ( overlock up to 20 ths) Firmware. 5 IP Address: Double-check that your Antminer S9 is using the correct IP address and that it’s not conflicting with any other devices on your network. Also you will need to get a 6” to 4” adapter. The miner stops hashing just a few minutes after boot up, I am guessing due to high temperatures as they climb quick up to 99 before the hashing stops. With high-quality construction and customizable fan control options, inline duct fans provide efficient cooling while keeping noise levels significantly lower than stock fans. Still weird how S9's control board started seeing 3 fans when one malfunctioned. The fans keep going all the while so there’s no let up of noise unfortunately but you can stop things overheating if it’s looking a bit too hot, without having to muck about with mains switches which may be in inconvenient locations. It is just slightly louder than I would like in some parts of the house, so I would like to have the fans run a little slower. com Open. fans checking was carried out and the limit for 500-800 rpm was added(it happened that the back fan was disabled, but it was This adapter will let you replace the 120mm fans with some hopefully quieter 140mm fans of your choosing. News: Voting for pizza day OC AsicBoost Antminer S9, T9+ Bmminer - Deploy Tool and access to set freq, volt, Fan Disable (Read 23661 times) thierry4wd. The kernel log shows that the number of fans is less than 4, or the user panel shows that the fan speed is 0. Antminer S9 - Actual CFM at full fan RPM . When the fan shuts down every minute or so the miner fans do this. Antminer S9 | | (Review/Guide) Antminer S15 | | (Review/Guide) AvalonMiner 741 | Hi, I just made some binaries for our Antminers S9. Reason: A heat sink is loose or falls off. Overview The AntMiner S9 is Bitmain’s newest version in the AntMiner S9 series. It turns on and connects to the internet but shows no mining status data at all and doesnt show up on nicehash and the Normal LED doesnt light up at all. i have s9k get profit around 10usd per month as asic eat alot power. If you find it useful, make sure you drop a thumbs up and share it. Try to google some sentences what it says. Application 1919 "antminer s9 fan silencer" 3D Models. This air duct is specially designed for the dual 120mm fans of the Antminer. Regional settings. 54 BMminer Version Uptime 7 Load Average 0. I’ve currently limited them to 1000W each with ASIC boost and auto tuning enabled and each miner is hashing at ~10. 2, Iceriver KS5M, KS5L, etc. 0-xilinx-ge8a2f71-dirty #82 SMP PREEMPT Tue May 16 19:49:53 CST 2017 File System Version Fri Nov 17 17:37:49 CST 2017 Logic Version S9_V2. See profile for Version changes in the antminer s9+ vnish firmware release. 7) Fixed bugs when using Nicehash and improved #xnsub. Solution: Just fill in the value of the percentage in the back box, and check the previous check box and click Save. For those interested in the details, the latest S9s have slightly different fans front and back. fonctionne OC AsicBoost Antminer S9, T9+ Bmminer - Deploy Tool and access to set freq, volt, Deploy Tool and access to set freq, volt, Fan Disable (Read 23662 times) alex1560 (OP) Member Offline Activity: 67 Merit: 24. Reset button and IP Report button have no effect. Solution: (1) Check whether the fan cable and extension cable are connected properly and plug them in again. Will it work? (Read 103 times) mara4fun (OP) Newbie Offline Activity: 1 09:11:30 AM #1. me/Abolfazl924 or telegram acc:@abolfazl924 It is suggested to unplug the front fan and remove it from the so it will not block the into the . Personally I’m under-volting mine to 8v in order to reduce temperatures and constantly be able to run the fans at 50% at 10TH/s with fresh air intake and every time I start the miner the fans go to full speed as a precaution, if you Download Official VNISH Bitmain Antminer L3+ firmware. We have summarized relevant content references for these four common problems to help everyone analyze the causes of miner failures and provide effective solutions. Turn off the power and check whether the power I am new with antminers. The following failure phenomena are from the Antminer S9 series of mining machines, and other Antminer models are for reference only. Does anyone know how to change the fan speed on a S9J? I asked this question last year for the regular s9 miners and it worked great. Also, check all your cables, maybe try only one by one hasboard connected. If you don’t, it I have this exact same thing happening. Ships from outside UAE. Bitmain FULLY SILENT Quiet Antminer S9 with noiseless PSU (or apw3++ on request) Bitmain Antminer S9 - SILENT Tuned with Bosminer 1Th @ 69w :fire: OR LESS Noiseless 6) We made a conclusion of information about dead fans in our own log. The fan check should be turned off when using immersive cooling (putting then entire miner in a liquid for cooling purpose). Solution: Switch the control board connection between the two fans to find out which one is defective. Any recommendations on what I can do with these? You can also see the out take fan pipes on the right side of the wall. You can verify this by connecting another device to the same network and checking for connectivity issues. We added a unique PROTECTION !!! opportunity to disable the timer (stage 3) in profile was added; fans checking was carried out and the limit for 500-800 rpm was added(it happened that the back fan was disabled, but it was rotating due to the stream from the My S19 only turns the fan down to 4000 rpm, even though the outlet temp is currently around 55 degrees. November 21, 2018, 09:23:07 AM Antminer S9 silencer thingiverse. jahxd November 07, 2021 16:56; Edited; 观察风扇工作正常,但就是没有算力。 every_chain_disable_PIC16F1704_dc_dc_new The Antminer S9 fan measures 120mm x 120mm x 38mm and operates at 12V. What can I do? I did : - Exchange between powers supply and issue remains. 00 AED 188. Personally I’m under-volting mine to 8v in order to reduce temperatures and constantly be able to run the fans at 50% at 10TH/s with fresh air intake and every time I start the miner the fans go to full speed as a precaution, if you turn off the fan-test setting this should, in theory, work. Overview 1. Also, before actually plugging your PSU into the wall, makes sure Download official Antminer S9, S9D firmware. Having said that, in most miners I dealt with, saving the configuration settings whether you are adding a new pool, changing the worker or altering the fan speed, the miner will actually reboot itself or at least reboots the miner's software (Cgminer /BFGMiner), and that alone is good enough to activate the setting, but for a few miners you actually need to hit the reboot Antminer S9, S9I, S9J, S9D VNISH official firmware. l antminer s9 fan silencer 3d models . 7A 6000RPM) 6500 RPM Fan for AntMiner DR3 L3+ S9 S9i S9J S9 SE S11 T15 S15 Z11 S17+ S17 Pro S17e DR5 D7 Z9 AsicMiner Misieren BRUSHLESS SHLF1212GHE-07 Sorry for the really soft voice recording in the video, please refer below for the written instructions:You will need to download Putty and ssh to the IP of 3) If you need to disable the fan control and remove the fans you must enable the Fan RPM check: fan check turn off (only for immersion cooling) 4) If you want to enable hashrate control function you need to set the value at which the firmware will reload the ASIC if the chains does not show the required hashrate, Restart if As far as I understand its only temporary while it reconfigures itself to your settings. c:9099: chain[6] has freq in PIC and will jump over main. Antminer S9 Noise Reducing Shroud The Antminer S9, a popular model among Bitcoin miners, can benefit immensely from a properly fitted noise reducing shroud. Resultados para antminer s9 fan ¿Buscando antminer s9 fan? Este ventilador es un gran accesorio para el motor del mercado. (2) If the problem still exists after You don't have to remove or add any code; see the comments below the code for more information. Power supply and ethernet connection are known to be good. Regularly clean your Antminer S9 to prevent these issues. Because the fan noise is so loud, I could not rent out the room to a roommate. Unboxing the PSU: (I use the 1600 t2) After taking it out of its packaging, find all of the cords labeled “VGA” and find the cord that would hook up to Product description: Antminer s7 s9 s9i m3 v9 d3 a3 t9+ miner Water Cooling Kit For DIY Liquid Cooler Heatsink To improve mining performance, one of the most important things is to cool the temperature of the miner. Shazam!!! Full Member Offline Activity: 350 Merit: 158. When you want to remove an asic, you need to remove the heat sink from the back of the board first. It may be that the fan is damaged or the power cord is not plugged in. 0 your firmware might be corrupted. There should be some shaking which may be loose fan screws, loose fans, the cpu/control board, or each processing board. S9 motherboard pdf manual download. 465 INFO Hashboard IP core initialized Hi just online back again because i need help to experience how to fix the antminer s9 always restarting? After that set the fan speed to high speed you can find the fan speed in secret menu if you don't i am 100% sure that many of my S9s rebooted a few times when temps where high. It has since become one of the most popular and widely used miners in the world due to its high hash rate and low cost of Personally I’m under-volting mine to 8v in order to reduce temperatures and constantly be able to run the fans at 50% at 10TH/s with fresh air intake and every time I start the miner the fans go to full speed as a precaution, if you The Antminer S9 is a machine that was released by Bitmain in 2016. If they’re malfunction ing or not If it's running fine the other option is if fans are running fine then you can disable the fan check by switching to Braiins OS or any custom firmware that can able to disable fan check. The Antminer S9 fan is a crucial component of the device, ensuring optimal performance and longevity by providing adequate cooling. Power Antminer S9 Neither the red light or green light turn on after reset Antminer S9 Neither the red light or green light turn on after reset (Read 247 times) SenatorDoom26 (OP) Newbie Offline driver-btm-c5. 05 Personally I’m under-volting mine to 8v in order to reduce temperatures and constantly be able to run the fans at 50% at 10TH/s with fresh air intake and every time I start the miner the fans go to full speed as a precaution, if you Where it ends, there may be some helpful information. Normally, I get $1100/month for the room. opportunity to disable the timer (stage 3) in profile was added; 7. You will need antminer fan simulators otherwise am os will think the fans are unplugged and not start. err bosminer[17909]: May 05 03:05:58. After saving, you need to restart the miner to take effect. 464 INFO Hashboard 6: bm13xx 1. image Show only one fan - The reason is that the miner only detects a fan and protects it. Please login or You can remove/replace both fans without touching the warranty stickers. S9) fan problem solution. 1A, 209CFM, 6000RPM, 65. Getting about 15. It boasts a state-of-the-art BM1387 custom-made chip using 16nm technology. Re: Antminer S9 cross flow fan mod. 0. This system ensures that the generated heat is quickly and effectively removed from the core components, maintaining them within safe operating temperatures even under continuous operation. Z11. Anonyme. It works with Antminer AL1, S21, T21, S19jXP, S19kpro, S19Pro++, L7, S19Pro, eBit 10. Using bitmains psu. The fan speed is too low. Asiukas6 June 19, 2020, 5:23pm #15. aryangarg1000 (OP) Newbie Offline Activity: 13 Antminer S9 Replacement Fans . Members Online. Antminer S9's fans spin when power is applied, but no lights turn on (no hashboards, no ethernet, no status leds, no controller leds). The 140mm fan is centered in such away that the miner will sit on the fans sides. 5 TH/s, it was the dominant machine at that time. Old version lower than 2019 firmware(2018 to 2017 firmware) doesn't have a signature that is why you are getting this "Cannot Find Signature" View and Download Antminer S9 repair manual online. About Us; Features; Partnership; Firmware. I want to allow boot with 0 fans passed, but also keep them powered (I don't know if immersion What I'm looking at is a way to either: a) run the S9 without fans and without taking that additional power that the fans draw. I notice is seems to give you the option to manually set the fan speed in the settings, but it doesn't seem to do Antminer S9 - Exhaust Fan Will Not Exceed 600 RPM I have one S9 with a fan that will not go faster than 600 RPM. This is a quick way to check whether the watchdog timer has expired and disabled the dc-dc converter output. 3. Connect the power adapter to an outlet with its own on/off switch and turn it on. Fan-operated subreddit. To solve the noise problem of Antminer S9, straight-through noise reduction boxes, labyrinth noise reduction boxes, and water-cooled and oil-cooled noise reducers can be used. Our firmware has a much wider range of features. Stable: Automated voltage tuning for best hashboard stability and performance. Most am fans are 220 to 250 cfm. There is no use resetting the router. This adapter will let you replace the 120mm fans with some hopefully quieter 140mm fans of your choosing. BITMAIN is the world's leading manufacturer of cryptocurrency mining servers through its brand ANTMINER, which has long maintained a global market share and leading position in technology, serving customers across over 100 countries and regions. What actually shown in the hardware version? Sometimes it's a firmware issue if your hardware version is X. Refresh Processing Time: ~2 business days. Unscrew and remove rear fan. Dracaena 2 Pack Replacement Bitmain Fan for Antminer S9, T9, Z9, D3, E3, X3, L3+, 4pin, 120X120X38mm Cooling Fan, DC12V, 2. DONATE: If you want, you can make a donation via Ko-Fi Decrease quantity for Antminer S9 — 140mm Fan Grills Increase quantity for Antminer S9 — 140mm Fan Grills. I only have one 110 volt electrical outlet. Just printed this part and added to the output fans, and now I am thinking to add also the same part to the intake fans with a quiet exhaust I had. I've also started having YaLn (Yate Loon) fans fail and completely stop. Antminer S21; Antminer T21; Antminer S19; 7. AED 188. Then slightly bare the yellow wire (using a lighter flame to soften the plastic Fans & other Antminer spare parts; Antrouters; Antminer kernel log This method applies to Antminer S9, T9, L3+. Checked all cables and reloaded firmware, still not showing. These are 9 too loud, go for d3 and use the blissz firmware on "Silent" mode, if you keep the miner cool have the three boards (40-50C) the fan speed will be 3000-4000 RPM which is a whole lot quieter than s9 which has an average of 5400-6500 RPM (80 dB vs like 65 dB) How to view the kernel log: After entering the background of the miner, click "System", and then find the "Kernel Log" option. I see a bunch of modded S9 on ebay that claim to do this. Here are the detailed specifications of the Antminer S9 fan: Dimensions and Compatibility: The Antminer S9 fan measures 4. And remember, sometimes it takes up to 20 minutes to antminer finish all tests and start hashing. If this function is not checked, how is the fan speed of the miner controlled? In fact, the fan of the miner is automatically adjusted according to the temperature by default. 72 inches (120mm) in length and width, with a height of 1. watch what to mine and you see profitable or not. To increase the profitability of equipment up to 50% opportunity to disable the timer (stage 3) in profile was added; fans checking was carried out and the limit for 500-800 rpm was added(it happened that the back fan was disabled, but it was rotating due to the stream from Easily power your Antminer S9 with the right type of PSU, ensuring efficient mining performance and optimal energy consumption. Unless the miner is UC/UV'd there is no getting around this. AFFILIATION: Make your purchases online by clicking on our affiliate links here Amazon. Chip auto-tuning. 5Th/s and fans Turn off fans Ability to disable polling fans during immersion cooling (no tricks needed) Bulk password change Bulk Change Password, SSH Port, and Disable SSH Port (Additional Security) Antminer S9 S9i S9j. or b) run the S9 with the fans, but disable them so they don't take Antminer (S17. DONATE: If you want, you can make a donation via Ko-Fi Official Vnish Firmware for Bitmain Asics (Antminer S21, T21, S19, S19 hydro, T19, S17, T17, S9, T9+, L7, L3+, L3++) | We offer to download professional VNISH firmware. I have an exhaust fan sucking the hot air out the room that auto cycles based on the temp in the room. 2 is 2% and 90 is 90% with a max of 100. VoskCoinTalk Bitmain FULLY SILENT Quiet Antminer S9. Mining & Hardware. Bitmain. 7Amp Power Connector: 4pin Product Specification Item Dimensions LxWxH 4. With the added advantage of efficient heat management, your S9’s operation becomes much more suited even for noise-sensitive environments. Bitcoin Forum: December 14, 2024, 09:34:16 PM: Welcome, Guest. That means they have to produce high static-pressure which is why they run high rpm. If enabled, the firmware will only start the mining if the fans are working correctly. Check the rated fan speed that could be the issue. 4 out of 5 stars 97. Reliability. I decided to compile bmminer from official bmminer GitHub repository and since I am no programmer, I am unable to pass per-board parameters, so all binaries have fixed voltage for all chains, it requires only one fan and 3000 RPM max is Прошивки AntMiner s9/s9i/s9j pro 5. 0 yesterday) Kernel Version Linux 3. Dimension of outer the frame is 120mm(L) x 120mm(W) x 38mm(H) Ultra-high-speed, 6000 RPM High Airflow Fan. It is enough to unscrew the cover / holder directly. If a fan blows in the wrong direction, remove it, turn it around, screw it back on, and it will blow in the right direction. (In the miner status shows snowflakes icon, and now you can see the rmp if you did not remove fans in oil) Remove. Hash rate is normal. Mount the adapter to the chassis first, The Antminer S9 employs a robust cooling system comprising high-speed fans and heat sinks strategically placed over the BM1387 chips on the hash boards. Usually manual (true) is the best for our purposes. 72 x 4 Antminer S9 - Stops hashing after booting up - Pretty sure it's a fan issue. i think your scenario happens when you check " stop Solution for ANTMINER S9 FANS SPEED Up & Down every 20 Seconds. Re: OC AsicBoost Antminer S9, T9+ Bmminer - Deploy Tool and access to set freq, volt, Fan Disable . If necessary, replace faulty components or consult a technician. edxm vwwo nbynh lzv mbpkuvy fuo kvix xadf wqvrm uchvz