Revit set underlay to none A link can be set to Halftone to distinguish it from the main model, but new work (model lines, for example) can still end up being obscured by geometry (walls, etc) in the link--making it difficult to see what you've drawn. so all the help would be well appreciated N When Underlay Orientation is set to Look down, the underlay displays as if you are viewing it from above, like a plan view. For each floor plan that the family extends to, set the Underlay to none. My underlay is set to plan. I want to find an API that will set the underlay for all views in a model to NONE. If you set that to none, the pipe will probably fall away. Its quite a pain to remember to set this each time a view is created, but more of a pain to have the newer guys on Revit waste their time and mine troubleshooting. You'll notice that the new linework remains. - Check View Range of the Struct. Mar 30, 2017 · Have you set the underlay setting to none? Otherwise you will have to check your view range. So let's say maybe we want to have some kind of a light fixture over the toilet here. Set visual style to wireframe. On the Properties palette, for Underlay Orientation, select Look Up or Look Down. On the Properties palette, for Range: Base Level, select the level you want to underlay Feb 26, 2015 · So for example, I have my view depth of my second floor plan set to -4'-0" with level 2 being the associated level. I figure this has to be a Discipline issue, but I have it set to "Mechanical" Discipline, so sho Apr 1, 2021 · My view range on the overall plans go from 0 to 10', so shouldn't be showing anything above or below each level. chilenito. May 14, 2019 · RevitForum is a vibrant community for Revit users of all levels, and the best part? It's completely free to join and use! We keep the platform ad-free for signed-in members, to ensure a smooth and distraction-free experience. room tags and they are set at level 0 and level 1. How can I get these beams to show up on the floor plan with the cutting plane set at 4'. I messed with settings and closed Revit and restarted the computer, but nothing works. My Revit model is 100% made up of Linked models (about 10) as we purely use it for documentation purposes. This issue occurs because there is an incorrect view range in the main view. The Underlay Orientation is Look Down. Mon, May 31, 2010 at 1:47:26 PM | turning off levels below current on your sheet view Course Files Download Linkhttps://www. hth-----best regards, coreed,aia. May 7, 2014 · Hi Guys. Set this to "Reflected Ceiling Plan". i drew this in revit architecture 2015. I elevated the family (it is just a square boundary) to 2' above the cut plane and I still couldn't select it when I had Select Underlay toggled off. iamian33. Maybe check your halftone setting? Ribbon: Manage > Additional Settings > Halftone/Underlay Also may want to set your Underlay to None. We have floor plans and in some of them we need to show an Underlayed Ceiling Plan. Apr 10, 2018 · When using Revit's Underlay (to see another level/view), it would be very helpful to be able to change the colour. . If this kind of problem occurs in a 3D view it's because of large coordinates, mostly from a DWG link that's visible in the 3D view. I checked the object styles and the VG menu and they are both the same as the ductwork yet appear to be greyed out (see below). not only show up on the floor they were drawn on but also on other floors where they are a real problem. Attached is a photo of what my apartment room visibilities are set to. When I change the underlay from "none" to the actual level that I am on, they go half tone and cannot be selected in a window, only by clicking on them manually. Frequent question, how do I use … Jan 17, 2022 · Join the FREE Architecture Vanguard Skool Community https://go. When you set an underlay, Revit LT displays another level of the model at the view's cut plane under the current plan view. If the view range intersects the geometry of a level in your main view, that level cannot be used as an underlay in the main view. To get full access to all the features, please register for an account. Views to make sure cut plane/view depth is set correctly so underlay of lower level/level below could be visible. Range: Top Level is automatically set to one level above the Base Level. What parameter should be set to none, in the View Properties dialog, if you do not Linework Tool – Use “Underlay” solution in combination with Linework tool to change style of beam projection. Reply. Study with Quizlet and memorize flashcards containing terms like It is not possible to copy/paste elements from one floor to another and have them line up with the original objects. My question: What determines what shows when you pick an Underlay and set Underlay Orientation to Plan? Is it the View Range of the current Plan? The View Range of the Underlaid plan? In the Project Browser, open a plan view. Underlay is set to none. The View Depth Level is set to Level Below (1st Floor). I already set the underlay to none but still shows up. Feb 3, 2016 · Sorry Wrong pasted image above and cant edit it . Go back to the Underlay setting and change it back to "None". com/My Revit project files: https://www. WORKFLOW: 1. View depth = -4'-0" and Underlay = none. Registration is fast, simple and absolutely free, so please register today! Apr 30, 2012 · Yep, expect to see underlay play havoc on all your levels as it is automatically set on view creation to the level below that has a floor plan associated to it. I have two beams at Elev 8' to 9' (Top of Wall). When we desire to set it’s underlay to ‘none’, we simply set both it’s ranges to a non-existent element by providing InvalidElementId value. Is this possible? (Using Revit 2014) We would like to show you a description here but the site won’t allow us. Make sure the Underlay (in the properties) is set to none /r/Revit A place to talk about anything related to Revit. Create a Temporary Level 2. All community This category This board Knowledge base Users Products cancel Feb 3, 2020 · leave the underlay settings same to what you posted earlier; use Wireframe; Option 3: Add a level at the bottom of the slab (BOS) as mentioned above; Attach walls back to floor @ level 3 or set top constraint to BOS datum; set the underlay top to the datum @ BOS (this will cancel the floor slab @ level 3 from the equation Jan 26, 2017 · My "Range: Base Level" is the 1st Floor and "Range: Top Level" is the 2nd Floor. 0 Likes Link copied. Underlay should be set to none by default. This video demonstrates the following: Set an underlay for a view. Hope Jul 10, 2015 · Out of the box, Revit doesn’t do this because Revit shows it as it’s built. This makes it a pain to check/manage but you can use dynamo to set it to none for all views; Topic: Setting underlay parameter to null | Dynamo BIM Aug 16, 2015 · I want to have a plan view showing the base in section ,and the top as an dashed overhead dashed line. The following screencast demonstrates this using Revit 2017: So basically I'm placing floor drains, now if you don't set the view range to a negative value the floor drain wouldn't show up in plan view. when i go to level 2 the floor plan is visible and interferes when i try to draw in Aug 3, 2005 · I had a similar thing with a wall - it was the phasing, I had accidentally set the wall to be demolished and my phase filter was set up to make demo transparent. Mar 17, 2023 · I have a lot of views in my project with different underlay base level and I would change it to none for all the drawings. com! - Tutorials, Tips, Products, and Information on all things Revit / BIM Also try setting underlay to none to see what happens. through my own and then looks messy. and more. Usually something like the floor below/above in greyed out mode. I've never understood why it's a default setting to have it on - set to the floor below. Underlays are one Apr 30, 2012 · Can anyone tell me how I can change a model I have recieved from another company. patreon. Is it that? Looking at it there are lots of dotted lines - looks like could be a view depth issue too? play about with the view depths. Click Apply. Fri, May 18, 2007 at 6:00:15 PM | I SEE 1ST FLOOR FROM 2ND FLOOR PLANWHY IS THAT? #4. When the Underlay Orientation is set to Look up, then the underlay displays as if you are viewing it from below, like a reflected ceiling plan. In this example I open the reflected ceiling plan of Level 2, and then add the floor plan of Level 2 as an underlay to see MEP components whilst setting up the skylight on the ceiling. Louis. Host view should apply the settings of your current view to the linked model. Using a Revit link as an underlay can be a common workflow for architects and especially for engineers. Here's where I find it even more confusing. You can either turn off some of the stuff and leave the exterior walls as gray scale, or you can use the linework tool and select the exterior walls to make them dashed (there's a linetype called <above>). The beam should be visible now. Aug 6, 2018 · In Properties, there is an Underlay set. Look in the properties of your floor plan View and set Underlay to None. Some may call this WYSIWYG or, what you see is what you get. if you have the underlay option on, you will have to go to that view and in the view proprties set the underlay to none. Dec 20, 2017 · Today I came across a very strange occurrence. Are you not able to use underlays unless you have “floors”? Jun 29, 2014 · For example, you place this family on level 1, and then you can see the lines in level 1 plan view. Any fix? When Underlay Orientation is set to Look down, the underlay displays as if you are viewing it from above, like a plan view. That did the trick, thanks I played around with the underlay settings before without stumbling upon that configuration apparently. Nov 13, 2018 · Where view is our floor plan to be modified. Check to see if its set to By Host View, Liked View or Custom. "Revit has to be implemented, Not installed. 90% of views never need an underlay. I believe that if we can adjust the colours, we can better communicate that there is an underlay in the view. I see you have your Base Level Range (Underlay) set to ground. 00 The building elevations are : GF - 0 1F - 3600 2F - 15700 RF - 10650 I must admit im still trying to get to grips with view depth / range etc. I can see the Roof above, but I'm expecting to see the Walls. The underlay appears in halftone and is visible in a hidden line view. Oct 7, 2015 · Using Revit 2021 here, but I think this should apply to previous versions as well. Apr 26, 2023 · I have 2 floors below that I am working on and it would be extremely useful to be able to see them no matter what floor plan I am on. In 2012 revit, architectural drawings were set as underlay and will show up fine even under the structural slab. All my existing levels have their underlay display property set to None, but the new ones all have it set to the previous level. To do this, set the underlay to the current level, and the set the plan orientation to Reflected Ceiling Plan. Jun 12, 2014 · This is whether my underlay is a plan or RCP. Now, I try that same philosophy on the third floor. Works fine. comUnderlay set to noneWhen a new floor plan is created, Revit automatically sets the underlay to the floor Jun 27, 2016 · PREPARATION: First Download the "Archi-lab_Grimshaw" package. All my existing levels have their underlay display property set to None, but the new ones all have it set Jan 31, 2012 · You probably have an Underlay turned on. Hit OK and your done. If top , cut plane , bottom and depth level are all set to associated level and depth level is also set to associated level and all offset are given zero mm ; this means I should not be able to see anything below associated level ; But I'm seeing everything below assoicated level . If you want to change the color of the lines of an imported underlay do this: Visibility/Graphics (type VG) Jan 11, 2012 · With Discipline set to Mechanical, Plumbing or Electrical I see the walls, doors, and windows half toned. This should be set to none, but there is no option on any view templates to set this. This user is offline . Welcome to RFo! In the main level plan, turn on the underlay (in properties) for you second floor. Mar 12, 2025 · Each Revit view is saved as a separate file on your hard drive. Oct 8, 2023 · When you tried to underlay a floor, only doors and windows were visible. Comment Post Cancel Jan 12, 2015 · Mon, Nov 9, 2015 at 10:32:43 AM | Revit 2015 - Underlay set to NONE #1. The same thing happens if I try adding these underlays to the 6th or 7th floors as well (with the added problem of "underlay orientation" also being greyed Aug 12, 2011 · Here is a short and sweet question handled by Joe Ye: Question: I am creating new levels using the API. , Revit's dimension tool can snap to the middle of a door opening without the need to draw a If I set it to Underlay, the linked model is gray (yay!) but my slab being "over" the underlay, hides all of their walls, fixtures, etc (boo!) I just want to control which elements of theirs I see with the Display settings, it all to be gray, it all to be visible, but truly be in the background. If Underlay is already set to None, you either don't have a Floor modeled, and/or your View Range is too deep. All other choices are absolute. Jan 24, 2018 · I've tried setting the elevation of the object between the cut plane elevation and the top plane but it still is set as an underlay. I realise that setting up "Underlay = Level X" and "Underlay Orientation = Reflected Ceiling Plan" doesn't work. Oct 8, 2023 · Load that “host” family into the Revit project. Mar 15, 2024 · Welcome to Autodesk’s Revit Architecture Forums. Apr 9, 2020 · That Underlay is to have the ability to adjust the brightness or tone of the lines of a linked model. Sep 3, 2010 · In the beam family, add a symbolic line in the center of the beam. , Changing an instance parameter affects the selected or to-be-created elements. I was using the plumbing template and I a few families come out in grey. Participant in reply to Anonymous Study with Quizlet and memorize flashcards containing terms like You should start drawing your floor plan generally centered on the default elevation marks in a new project. com/U6TNgIIn this video, we look at using underlays. Note: This video was recorded using Revit 2017. when i place a new room tag in the space above at level 1 and name it 'flexible academic space', it changes the room tag below to match it. and my view range is set to : ass level - 3600 cut p - 1500 bott - 400 view depth - 0. Mar 1, 2024 · Now we know the basics of the Revit Underlay and its purpose, let’s continue by adding an Underlay to a view. New plan views will have their Range: Base Level set to None. Set it to structural and they or off. In the example below, I use a reflected ceiling plan to position my lighting fixtures and add an Underlay to enhance the visibility of the furniture for better positioning of the lighting fixtures. Visibility/Graphics -> Linked Files -> Change the file to Custom Settings, go to the Model Tab in there and change the color of the cut lines and cut patterns as desired. My suggestion was to turn on the underlay so that the elements in question could be seen. Drop-down “Range: Base Level” to select an underlay. Jan 15, 2012 · Hi, I'm new to revit so sorry for such a noobie question, is it possible to hide walls/doors/etc. parathkrishna. If not set to Underlay the height order of linked objects is respected in the draw order. Jul 10, 2015 · In residential architecture, as well as other types, it is often a required part of the working drawing set to be able to show the roof overhang as a hidden line on the floor plan views. PS: if the view range of the upper level (here level 2) intersects/cuts the geometry in the lower level (here level 1) then all those elements which are cut in level one are excluded from the underlay therefore the adjustment made to bottom and "view depth level" to enclose all Jun 18, 2015 · cnd, A change was made to the default underlay setting for plan views. They aren't grayed out and are fully editable on the floors they weren't drawn on. To add an underlay to the view: Go to the Properties palette > Underlay. The underlay can be viewed from above or below the current level. For example: In the main floor level, the bottom of the primary range is set to main floor with an offset of -1 Aug 8, 2022 · Adding An Underlay. Any help is appreciated. So if I set the view range to 1800mm below level 2, if I have a slab that is 2200mm below level 2, I will actually see that slab even though it is not actually within the view range I set. Also look in the view's VG --> "Revit Links" tab. In the Project Browser, open a plan view. Aug 21, 2024 · Hi @KrzysztofSzalucha,. Great. Jan 30, 2006 · Goto the view's properties and change the Underlay from None to 2nd Floor for instance. For example, you may want to set an underlay for the casework in the kitchen to make it easier to place the light fixtures above. , It is not possible to copy / paste elements from one floor to another and have them line up (with the original objects). 3D View of Roof Dec 21, 2018 · -Try setting the View Template to None. Set underlay to none and visual style back to hidden Apr 12, 2011 · Things such as cabinets, roof vents, etc. Report. Set Overlay Par ok im almost a total noob in this, i started using revit today and finished drawing a ground floor plan for a house. To get Revit to do Welcome to the Revit Forum You are currently viewing as a guest which gives you limited access to view attachments, ask questions and access other features. So far I have changed my View Range Settings, changed underlay settings, tried changing and switching the view templates, set the phase filter to none, changed the visual style, and toggled hidden lines. Default is set to 'none' using 2016 R2. In case of some older Revit/Dynamo versions the code could look like so: view. How can I programmatically change this setting to None as well? Answer: This property is stored in the "Underlay" parameter on the level. -Also, check Discipline of the Structural Plan Views--default is Structural, perhaps try changing to Architectural or Coordination. When all of the wanted beams are overridden with Linework tool, set underlay property of the view to “None”. To get Revit to do this there is a simple work around that I have outlined below. Again, in both plan and RCP. When Underlay Orientation is set to Look down, the underlay displays as if you are viewing it from above, like a plan view. bmpArchitects,Inc. Share your knowledge, ask questions, and explore popular Revit Architecture topics. Please mention Revit version, especially when uploading Revit files. " Jun 19, 2013 · I am trying to create a sheet of floor plans that does not show the next floor down on each floor plan but I can't seem to find out how to do it. If you want to see it on other level views, you can go to that view properties, and set the Underlay as level 1, then these lines will show up in this level plan view. But if you put negative view range the underlay will show up. com/balkanarchitectGet my Personal Revit Template + Family Pac If Revit could do that automatically, that would be a better solution. Jun 27, 2022 · Get all Revit Courses: https://balkanarchitect. Jul 7, 2011 · From Autodesk Wikihelp for Revit 2012. You should be able to pick the center line of the beam with the linework tool. Meanwhile, can you confirm if you have the latest updates for you Revit version as well?. You will now see that the "Underlay Orientation" setting is no longer grayed out. I made a simple script in order to do that and unfortunately it doesn’t work. You set an underlay by specifying a level. Jun 10, 2015 · In the Visibility/Graphic Overrides in the "Revit Links' tab have a look at the display settings for the linked model. Assign the range levels for the underlay. Feb 2, 2009 · I have having this same issue on 2020; I see how it is associated with the underlay, but when I set the underlay to none I am still having the same problem, in fact the underlay was always set to none and the special equpment is coming out in grey. On the Properties palette, for Range: Base Level, select the level you want to underlay. May 6, 2020 · Setting model link to "Underlay" causes my model to appear transparent and none of my structural elements maintain their <solid fill> white background. If I set the underlay to 3rd floor, then my 4th floor slabs DO show up. It is possible in Revit or do I need to draw some hidden lines t Jan 10, 2017 · First your current view may have been set to show an underlay. This is a common issue and I've searched many blogs but cannot find a decent solution. Just using halftone does not solve this issue. However, the underlay is not displaying. With new revision this is not the case. The issue of Revit View Underlay setting has been bothering me for a really long time (well, not “really long time” but since I started using Revit Channel: Tutorials, Tips & Tricks May 13, 2013, 01:07 AM Feb 16, 2006 · the first thing to check is the properties for the view and set the Underlay to "none" HTH-----best regards, coreed,aia. I need my structural elements (bearing walls, fram What parameter should be set to none, in the View Properties dialog, if you do not want to see the walls from the floor below? Underlay The _______ ________ controls the size of dimensions and text, plus the scale that view is placed on a sheet. I don't think it's an underlay problem. Create an underlay when you need to understand the relationship of components at different levels for coordination and construction. Best answer for this question, how do you … Jan 7, 2016 · There is an Underlay setting for the view, most likely it is set to "None". Which F2 furniture are you referring to? Your solar panel structure is angular so in order to make the solar panels to NOT show the grey lines you can use a masking region for this. Set the view direction of the underlay. Aug 23, 2021 · So we know that there is an underlay here because it's shown in grey, and if we go over to the properties panel and scroll down a little bit, under underlay you can see that we have the underlay set to the first floor level. get_Parameter(BuiltInParameter. Underlay is not schedulable, so you have to check each view to see if it is on (And it is set to the level below by default for newly created views. Create an underlay to a view to reference geometry from other plan views of the model. I created a Level 2 in my project in hopes that I could show the upper portion as an underlay, but nothing appears when I set the underlay to Level 2. i have revit 2016 as well. bimmodeller. I am finding that users can get confused when Underlay is on or left on, and thus the underlay prints. When you set an underlay, Revit displays another level of the model at the view’s cut plane under the current plan view. Sep 7, 2015 · While it is possible to set the ‘Underlay Orientation’ within a view template, it is not possible to set the ‘Underlay’ to ‘None’. Dec 25, 2008 · Merry Christmas everyone. Here is a short and sweet question handled by Joe Ye: Question: I am creating new levels using the API. We can turn underlay off. Aug 6, 2014 · i have underlay set to 'none' i have a space at level 0 with a room tag named 'interactive space'. " Long Live Revit. VIEW_UNDERLAY_ID). It's some sort of visibility graphics issue but I can't Aug 13, 2015 · When any new views are created in a project, underlay is automatically setting to the floor below. Instead of of just a fixed half tone. from the lower floors? When I'm looking at the 1st floor, I can see all the details of the ground floor, making it look too cluttered. active. Out of the box, Revit doesn’t do this because Revit shows it as it’s built. Now use the linework tool on the edge of the balcony above and turn off the underlay. You can set the Underlay to none when you don't need to see it for reference. Temporarily set the Underlay to another level, any level. now my problem is i drew the ground floor plan in level 1. Dec 11, 2017 · Hi @Anonymous . "One must imagine Sisyphus happy. Nov 27, 2012 · Revit Tip - Floor Plan and Ceiling Plan View Range Explained | TheRevitKid. I don't even want to change the services I just want to change the underlay to none so I can export it to CAD. The first Underlay feature does not work with linked models, only in the same model. Joined: Wed Mar 9, 2017 · Quick test, set your View Discipline to Electrical, can you select it? Or just for easy reference, set your View Discipline to Coordination. Use the Underlay parameters on the Properties palette to set an underlay. My lecturer said it made the floor plans 'confusing and difficult to read' but other than photoshopping them out or something I'm stuck See attachments for exactly what I mean. This can also happen in Elevation/Sections, but if the DWG is turned off in those they "recover", with 3D view they mostly don't because the settings of the view have gotten to large coordinates (Eye/Target elevation) Apr 24, 2021 · Revit has underlay option in Floor plans to refer other levels . " Albert Camus - "The innovator has for enemies all those who have done well under the old conditions, and lukewarm defenders in those who may do well under the new. , Each Revit view is saved as a separate file on your hard drive. Place it at the base level that corresponds to the reference level of the host family. architecturevanguard. Three of the underlay options (Current Level, Level Above, and Level Below) are relative to the current level. If you set Range: Base Level to "None" under the Underlay settings on Properties this will correct the issue. Aug 8, 2016 · When a new floor plan is created, Revit automatically sets the underlay to the floor below. when i select the room tags, you can see 2no. Pros: Good solution which “follows” overridden beam if it’s type is changed. (T/F) Underlay. If you apply that Underlay, you can adjust the tone of linked models in Manage > Additional Settings. ). Joined: Tue, Nov 17, 2009 148 Posts No Rating. Oct 7, 2015 · Firstly I am finding that when I set a bottom view depth, Revit will actually show slabs that are close to (but not actually included) in that view range. Aug 8, 2016 · When a new floor plan is created, Revit automatically sets the underlay to the floor below. Used both Underlay and Plan Region with different View range. Meaning that in the real world we don’t see a dashed lines on the ground so we know there is a roof above. See Mar 29, 2018 · All levels offset on zero and my reference level is on associated level . I want these two beams to show up on the floor plan as hidden lines. May 5, 2017 · Hello, I seem to have a problem with my duct fittings coming in greyed out. I have the overall building link and the apartment links set to "by host view". Greetings. This limitation seems like a pretty massive oversight from Autodesk and defeats the purpose of having view templates in the first place. In the project, set view underlay to the current level and RCP underlay orientation. A linked model can be set to half-tone and/or underlay, in addition to customizing what is shown. You can set it to None by Dec 7, 2010 · Normally, you would turn off the underlay before exporting or printing the view. Underlays are also useful for working with MEP models, since you can work in the Floor Plan while viewing the Ceiling Plan as an underlay. The slice of the model between that level and the next level up displays. Jan 10, 2011 · I can see some items on the Underlay, but I expect to see exactly what the Floor Plan shows. BUT the second floor walls are showing up. If I change the underlay settings in the Properties window for a floor plan view it will affect both conduit and duct fittings. The underlay is set to "none" on all overall building views. Set(ElementId Oct 10, 2023 · Thank you for getting back to me, After reading your answer it struck me to check the transparency setting of the concrete walls under which the underlay was showing in dashed and it turns out that my walls had different transparency settings (completely forgot i changed the setting), when wall above was set to 0% transparency the lines would show dashed. Sections and plans both show the linked model hatching, etc. Lastly, I think it's probably your Level at what the Pipe was drawn. When you create a new plan view, the Range: Base Level is set to None. Ask questions about Revit software, standards Jun 20, 2011 · Our office just moved to 2013 Revit structure and we are experiencing the same issue. iawx ldbtb zzxohcli bjcezhx mkwif aygp scr czhvti vnrgupjy wrznwj dfur fhcjwn zdlif jrt wykrj