Collabora Logo - Click/tap to navigate to the Collabora website homepage
We're hiring!
*

Juniper snmp routing table

Daniel Stone avatar

Juniper snmp routing table. both Figure 2: Routing Instance Window. The EX Switch can be configured to fetch system time from NTP servers connected in the network. Junos OS is the network operating system that powers our broad portfolio of physical and virtual networking and security products. Feb 3, 2022 · The course then delves into foundational routing knowledge and configuration examples including general routing concepts, routing policy, and firewall filters. Junos OS automatically creates and maintains several routing tables. Dec 18, 2023 · Enterprises use SNMP traps as part of a fault-monitoring solution in addition to system logging. 50. This can result in many uninteresting traps, especially when there are Mar 9, 2017 · set snmp traceoptions file snmp-traces. MAC IP flags: Identifies : statically installed MAC-IP entries. By default on an SRX, to perform NTP associations, you must use an IP address from the primary instance to source the NTP packet. 0/0 next-hop 10. To configure the device as a node in a Understanding Layer 2 Forwarding Tables on Switches, Routers and NFX Series Devices. 21 which translates to ip. For example, n-Resolve inet indicates that the specified route is used for route resolution for next hops found in the routing table. Dec 12, 2012 · In the output above, one can see that routes were added to the routing table as a result of configuring the IRB interfaces. Through lab demonstrations, students will gain experience in configuring and monitoring the Junos OS and monitoring basic device operations. The Utility MIB contains one table for each of the following five data types: You can use these containers MIB objects to store the data that are not supported for SNMP operations. 2, 10. SNMP MIB Walk of the jnxOperating MIB Table with Secondary Node Details. By default, the show route forwarding-table command does not display information about private, or internal, forwarding tables. Beginning with Junos OS Release 9. b . For example: routing-options { graceful-restart; } Oct 10, 2020 · In the Routing Fundamentals lab step 2. This topic provides details related to managing SRX Series chassis clusters using SNMP. Mar 12, 2018 · root@qfxsw2# run show ethernet-switching table MAC flags (S - static MAC, D - dynamic MAC, L - locally learned, P - Persistent static, C - Control MAC SE - statistics enabled, NM - non configured MAC, R - remote PE MAC, O - ovsdb MAC) Ethernet switching table : 1 entries, 1 learned Routing instance : default-switch Vlan MAC MAC Age Logical NH Jan 31, 2024 · Input your product in the "Find a Product" search box. inet Internet: regress@R1> show snmp mib walk ascii inetCidrRouteNumber inetCidrRouteNumber. 0 route to the address on the backup RE - but since it doesn't use the inet. Click the Add button, and a new window will appear as shown in Figure 3. The QFX Series standalone switches, QFX Series Virtual Chassis, and QFabric systems support standard SNMP traps and Juniper Networks enterprise-specific traps. IP address associated with the ethernet switching instance type. Management Ethernet interface (fxp0) is confined in a non-default virtual routing and forwarding table (SRX Series) —Starting in Junos OS Release 18. Mar 19, 2015 · To enable SNMP managers in routing instances other than the default routing instance to access SNMP information, include the routing-instance-access statement at the [edit snmp] hierarchy level: [edit snmp]routing-instance-access; If this statement is not included in the SNMP configuration, SNMP managers from routing instances other than the Junos OS can also announce the route to the kernel routing table (KRT) for installing the route into the Packet Forwarding Engine, to a resolve tree, a Layer 2 VC, or even a VPN. . Display overview of bgp information for a particular group. 1(2. 3, and 10. Only users who belong to the Junos OS super-user login class can enable SNMP scripts. SRX detected a high temperature at 16:07:26, but an SNMP trap was generated at 16:08:10 due to the 1 minute interval. In a traditional network, each switch performs an IP routing lookup, determines a next-hop based on its routing table, and then forwards a packet to that next-hop. Juniper Networks ® MX10003 Universal Routing Platform is a cloud-era platform that cost-effectively addresses the evolutionary edge and metro Ethernet needs of service providers, mobile, web-scale operators, and multiple-service operators (MSOs) with ultra-high-density 10GbE, 40GbE, and 100GbE connectivity in a spaceand power-optimized package. 0 table shouldn't make any difference: {backup} @1> show route forwarding-table destination 2. 0 and earlier have reached end-of-support (EOS). 3. Action. Starting in Junos OS Release 20. I realize now there is no snmp { tree under routing-inatances or logical-systems though so it was a weird way to say it. 0. The SNMP ObjectID (OID) is . If the intended routes are not visible in the route table, then check the configuration of the IRB interface. inet Internet: Nov 30, 2011 · I would like to only permit traffic to my server and block all other traffic. Options. 0 = Juniper MX480 Midplane Internet Backbone Router. Click the Software tab. There are several commands that you can access in Junos OS operational mode to monitor SNMP information. In Junos OS, you must configure a trap-group if you wish to use SNMP traps. The Use the show interfaces interface-name terse command to find the IP address of the default management interface. Simple Network Management Protocol (SNMP) is an internet standard protocol for collecting and organizing information about managed devices on IP networks and for modifying that information to change device behavior. 101. This topic provides the list of standard SNMPv1 and SNMPv2 traps supported by devices running Junos OS. It worked, but gave us a few thousand in the output, which is probably every MIB going. commit. How to troubleshoot the SNMP polling issue . configuration protocol igmp command to verify the IGMP protocol configuration. 25. The Juniper Networks MX204 Universal Routing Platform is an Ethernet-optimized edge router with 400-Gbps capacity that provides both switching and carrier-class Ethernet routing. This article shows how to monitor a Logical System session and resource by using SNMP. all. 0 = node1 midplane jnxOperatingDescr. slax or . show snmp. 1 include. 1 is in its own routing instance, both IP addresses are accessible from a remote management station (say it is a snmp poller with IP address 10. 1. Use the show route forwarding-table command to look at the forwarding table for next-hop information for static routes. S—Statically installed MAC-IP entries. • Configure and monitor a routing instance. ) Here is the hierarchy table for the routing table leaf: 1 - ISO assigned OIDs. py filename extension, respectively Multicast Configuration Overview. To implement Layer 3 VPNs in the JUNOS Software, you configure one routing instance for each VPN. Junos Evolved platforms typically support two management interfaces per Routing Engine. 10), i. Table 1 lists the output fields for the show ethernet-switching mac-ip-table command. The tunnel interfaces are a part of routing-instances. Hence, the routes are learned in the routing-table of the routing-instance and not the default routing-table. Use PING to check if the IRB interface is able to route packets inside the VLAN and between the VLAN's: By default, graceful restart is disabled. (Optional) Display the specified level of output. srx> show configuration | display set | match at-2/0/0. set snmp view allmibs oid . The ACX710 provides high 1GbE/10GbE and 100GbE First, SNMP can be done through a routing instance but you won't get full information. 1. Eg, you'll only see L3 interfaces that are members of that routing instance. Download software and get product support in our knowledge base. set lo0/0 unit 0 family inet6 address fda9::1/128. The name of the dedicated management instance is reserved and hardcoded as mgmt_junos; you cannot configure any other routing instance by the name mgmt_junos. Dec 18, 2023 · SNMP Architecture. From the configuration prompt, execute the below mentioned command to get the snmp values: Below is a full sample showing how to retrieve identifier, state, admin status, etc. 0/24 next-hop 10. The default reconnect time is configured in Junos OS as 60 seconds and is user-configurable. Jan 12, 2020 · Juniper routing instances are very useful when you need separate routing tables on the one device, for example to separate customers. Dec 19, 2016 · Looking at the backup routing forwarding table, main difference I can see is there isn't an inet. Select the Install Package as needed and follow the prompts. You can configure Layer 2 MAC address and VLAN learning and forwarding properties in support of Layer 2 bridging. The number of input IP datagrams for which no problems were encountered to prevent their continued processing, but which were dis…. set snmp routing-instance-access. In addition to these automatically created routing tables, you can create your own routing tables. Use the show system uptime node node-name command to see node-specific uptime information, where node-name can be re0 | re1 | fpc0 | all. Ethernet-switching table: 7 entries, 4 learned. But it wasn’t obvious to me how to poll the default table via an interface in a routing instance. 208. 0 is in default/master instance, lo0. Then click Add Row for each OSPF process ID (for Cisco) or routing-instance-name (for Juniper) that should be mapped to this routing instance. Note: By default, SNMP is not enabled on devices running Junos OS. When an SNMP manager receives an inform, it sends a response to the sender to verify receipt of the inform. ipInDiscards. jnxBoxClass. 1/32) and lo0. By default, SNMP is disabled on devices running Junos OS. To enable SNMP on a router or switch, you must include the SNMP configuration statements at the [edit snmp] hierarchy level. 3, the logical router feature has been renamed logical system. 0 = node1 PEM 1 jnxOperatingDescr. detail | extensive | summary. This course is based on Junos OS Release 21 The ACX710 Universal Metro Router is a hardened, fixed, and compact 1 U solution, purpose-built for efficient 4G and 5G service delivery and scale. 10. The RJ-45 copper port on each Routing Engine is indexed as 0, while the SFP fiber port is indexed as 1. The two Routing Engines are identified as re0 and re1. 29/32 next-table mgmt_junos. SNMP informs are confirmed notifications sent from SNMP agents to SNMP managers when significant events occur on a network device. root@jtac> show route 172. Jul 21, 2017 · Below is a message log when the temperature of SRX240 RE exceeded the yellow alarm threshold. 5 Gbps access port options are available to provide higher-speed options, especially when connecting to 802. 0 = node1 Fan Tray The values of the reconnect and recovery times indicate the graceful restart capabilities supported by the router. Second, Juniper announced recently that in the future you will be able to have a dedicated management VR. 1 inet. e. The Fabric Chassis MIB is based on the Juniper Networks enterprise-specific Chassis MIB that provides information for individual devices. • Explain the basic routing concepts. routing-instance-name —Name of the routing instance. 1, after graceful routing engine switchover (GRES), the new primary Routing Engine sends a single warmStart notification. By default, the device responds to an Address Resolution Protocol (ARP) request only if the destination address of the ARP request is on the local network of the incoming interface. (This works for me on Windows, so I see no reason why it should be different for your Linksys/openWRT system. A typical SNMP implementation includes three components: Network Management System (NMS)—A combination of hardware (devices) and software (the SNMP manager) used to monitor and administer a network. You configure the routing instances on PE routers only. Built for reliability, security, and flexibility, Junos OS reduces the time and effort required to plan, deploy, and operate network infrastructure. From the Type/OS drop-down menu, select Junos SR. You can populate Support Resources. The goal is to provide Management Information Bases (MIB) for monitoring a logical system (LSYS) session and resource. Juniper Networks EX Series Switches track clients on a network by storing Media Access Control (MAC) addresses in the Ethernet switching table on the switch. 1 it instructs to configure the ipv6 address: set ge-0/0/1 unit 0 family inet6 address fda1::1/126. SLAX and Python scripts must include the . The reconnect time is how long the helper router waits for the restarting router to establish a connection. SNMP Support for Routing Instances . You configure a router network to support multicast applications with a related family of protocols. To see the details, visit NorthStar Hardware Dates & Milestones. inet. 4. [edit protocols bgp] root# run show snmp mib walk bgpPeerTable. According to Juniper's document on Enabling SNMP Access over Routing Instances : "To enable SNMP managers in routing instances other than the default routing instance to access SNMP information Apr 2, 2012 · You can find the SNMP object name by using the following command on the Junos device: id@router> show snmp mib walk 1. Statement introduced in Junos OS Release 16. Table 1 summarizes the first Junos OS release that supports PTP on various Juniper Networks devices: Table 1: Precision Time Protocol Support. Having snmp { routing-instance-access; Description. Logical Systems enable you to partition a single router into multiple logical devices that perform independent routing tasks. After enabling SNMP traps on one of our production MX480 routers, I began receiving JUNIPER-L2ALD-MIB:jnxl2aldInterfaceMacLimit SNMP traps for a few AE interfaces. To configure the default routing instance on a logical system, specify the To define the routing tables into which interface routes are imported, you create a routing table group and associate it with the routing device’s interfaces. For example: jun@MGM003> show snmp mib walk 1 | match jnxBox. The default management interface is fxp0 or em0 for Junos OS, or re0:mgmt-0 or re1:mgmt-0 for Junos OS Evolved. Junos lets you configure SNMP polling of routing instances, so customers can poll “their” interfaces using 'instance_name'@'community'. Per JTAC, I was told this can be done in the SNMP hierarchy by doing the following: user@host# set snmp community TEST clients 172. Apr 26, 2012 · If this is a Chassis Cluster/HA environment, then there will be a separate suffix (9. 113. 1 include set snmp community Test view test set snmp community Test authorization The Juniper Networks EX2300 Ethernet Switch offers an economical, entry-level, standalone solution for access-layer deployments in branch and remote offices, as well as enterprise campus networks. e. set routing-options static route 10. 1 has been created and that sources 10. To download the archived NorthStar Controller and NorthStar Planner documentation for EOS releases, select one of the zip files from the table below. show snmp mib, which displays information from the MIBs, such as device and system information. 2/32), lo0. I think it's a Junos 16. Feb 9, 2024 · This article provides steps on how to apply ECMP for BGP sessions when the interface hosting BGP is inside a routing-instance. • Describe the routing table and the forwarding table. If you have configured a routing table, configure the OSPF primary Dec 19, 2012 · With the following ethernet-switching table as a reference, the procedure to identify which interface is learnt from which MAC address for a certain VLAN is as follows: {master:0} lab@EX10> show ethernet-switching table. Dec 17, 2019 · By default, Junos will use the default routing instance to send sFlow packets. Juniper Agile Licensing (QFX5110-48S, QFX5110-32Q, QFX5120-32C, QFX5120-48T, and QFX5210-64C)—Starting in Junos OS Release Evolved 21. 0 (1. To confirm routing-instnace involvement, please share below output. You (the network administrator) can confine the management interface to a non-default virtual routing and forwarding (VRF) instances. To enable an SNMP script, include the file filename statement at the [edit system scripts snmp] hierarchy level, and specify the name of a file containing an SNMP script. 51. Juniper Networks Devices. You can configure five types of routing instances on the EX Switch: 1. 3 - ISO Identified Organization. X; root@sw> show configuration system management-instance; SNMP configuration: set snmp view test oid . 0 = jnxProductLineMX480. root#run snmp mib walk bgppeertable. If you configure policy tracing as shown in this example, you can run the show log ospf-bgp-policy-log command to diagnose problems with the routing policy. 0/0 next-hop pp0. will have to work on that. The NTP client (SRX) will always build the association from the default routing table (inet. To use multicast, you must understand the basic components of a multicast network and their relationships, and then configure the device to act as a node in the network. From the Version drop-down menu, select your version. Start here to evaluate, install, or use the Juniper Networks® MX104 Universal Routing Platform, a router frequently used for mobile backhaul, metro Ethernet, aggregation, and enterprise WAN applications. I'm having a hard time finding what this might be affecting. You can create and name a group of one or more types of SNMP traps and define which systems receive the group of SNMP traps. Each routing table is used for a specific purpose. 252. • Implement static routes and dynamic routes using OSPF. Related Information. All very useful. The number of locally-addressed datagrams received successfully but discarded because of an unknown or unsupported protocol. Its high-performance, high-capacity, and hardened design makes it ideal for ubiquitous deployment in metro applications and telco cloud architectures. 12. The set of interfaces belongs to the routing tables, and the routing protocol parameters control the information in the routing tables. Configure the SNMP options and customize the behavior of BGP-related MIBs. SNMP - Configuration. 0: 19 destinations, 24 routes (19 active, 0 holddown, 0 hidden) snmp { in the root of the device's config tree; in the master routing instance and not under routing-instances or logical-systems. For example, the RJ-45 management Ethernet port on Routing Engine 0 is typically named re0:mgmt-0. • Describe the functionality of routing instances. Key topics include user interface options with Specify a routing instance for SNMPv1 and SNMPv2 trap targets. instance instance-name. Figure 3: Add Routing Instance Window. Enable a dedicated management virtual routing and forwarding (VRF) instance. Apr 1, 2021 · 1. 11ac Wave 2 access points. MX80 Universal Routing Platforms with model number MX80-P. The EX Switch is capable of acting as a client to some of the services such as NTP (Network Time Protocol), SNMP (Simple Network Management Protocol) and DNS (Domain Name Service). To view BGP routing information in the CLI, enter the following commands: show bgp summary. The manager polls the devices on your network as you specify for information about network connectivity, activity, and events. Junos OS Release. on vSrx1 and fda1::2/126 on vSrx2. How to pull SNMP v3 information from non-default routing-instance Juniper NorthStar Controller and NorthStar Planner software releases 6. 2. It looks like the MAC address limit for a specific interface is 1024, and this matches up with the results I get from 9. 2R1, the QFX switches support Juniper Agile Licensing. This article discusses how the polling functionality is available if the interface is part of a routing-instance. 0 = node0 Routing Engine jnxOperatingDescr. After you have committed the configuration and the source is sending traffic, use the show igmp group command to verify that static group 233. 4 have been accepted. run the snmp poll and then check logs using "srx> show log snmp-traces". jnxBoxDescr. 8. g. something feature. route 0. Nov 7, 2017 · Report a Security Vulnerability. To configure a routing instance within a logical system, specify the logical system name followed by the routing instance name. Jul 9, 2010 · To be able to perform SNMP polling inside a routing instance on the EX platform, refer to the minimal example configuration below : In the SNMP configuration, the routing-instance name under the community stanza and routing-instance-access are required. SNMP OID's for BGP monitoring. Symptoms. 2. 85. Junos Software service Release version 20. Nov 23, 2023 · Management routing instance is configured: root@sw> show configuration routing-instances mgmt_junos { routing-options { static { route 0. 41; show rotuing terse: Starting in Junos OS Release 20. interface-set snmp index. Unicast media access control (MAC) addresses are learned to avoid flooding the packets to all the ports in a VLAN. 6. For more information about traps see SNMP MIB Explorer. On the next step it issues a successful ping on the local interface. In Junos OS, the processes that maintain the SNMP management data include the following: A master SNMP agent resides on the managed device and is Juniper SNMP in routing instance Hi, I'm currently testing akvorado in our lab which is in a Junos routing instance, I see that I am getting "SNMP cache miss" errors increasing meaning no data on the frontend. The course provides a brief overview of the Juniper products and discusses the key architectural components of the Junos software. In order to access MIB objects and perform SNMP operations for the routing-instances, SNMP Aug 4, 2010 · That should be MIB II. This course is based on Junos OS Release 21 Sep 9, 2009 · NTP, SNMP and NAME services does not work under routing instance. To configure the minimum requirements for SNMP, include community public statement at the [edit snmp] hierarchy level. All targets configured in the trap group use this routing instance. For example, if the interface-set SNMP index is 67108866. Each VPN routing instance consists of the following components: VRF table—On each PE router, you configure one Ask questions and share experiences about ACX Series, CTP Series, MX Series, PTX Series, SSR Series, JRR Series, and all things routing, including portfolios and protocols. The Juniper Networks enterprise-specific Utility MIB, whose object ID is {jnxUtilMibRoot 1}, defines objects for counters, integers, and strings. The Juniper Networks enterprise-specific SNMP Fabric Chassis MIB (mib-jnx-fabric-chassis) provides hardware information about the QFabric system and its component devices in a single MIB. It offers an effective way to maximize the use of a single routing or switching platform. 0); instead of the custom routing-instance table. 22 /16 clients but block everything I need help to understand how Junos behaves in this scenario, say I have two loopback addresses, lo0. Health monitor feature is an SNMP feature that extends the RMON alarm infrastructure to provide monitoring for a predefined set of objects (such as file system usage, CPU usage, and memory usage), and for Junos OS processes. This configuration improves security and makes it easier to use the management interface to May 21, 2024 · This self-paced On-Demand eLearning course provides you with the foundational knowledge required to work with the Junos operating system and to configure Junos devices. Nov 28, 2018 · set snmp engine-id use-default-ip-address. 4R3-S10 is now available. RE: SRX320 - Can't get SNMP working. The show system uptime command is a little different in how it displays output in Junos OS Evolved. For example, from Active to Idle or from Established to Idle. 0/18. source-route-option; router {. If the routing instance is defined within a logical system, include the logical-system logical-system-name statement at the [edit snmp community community-name] hierarchy level and specify the routing-instance Sep 2, 2009 · Can I get information about MS-100 module via SNMP, as I can get it by commands "show services accounting errors" and "show services accounting usage" • Describe the functionality of routing and routing instances. 0 = 23 regress@R1> show route summary Autonomous system number: 65001 Router ID: 203. 0/16 user@host# set snmp community TEST clients 0. (Optional) Display routing table entries for all forwarding tables, including private, or internal, tables. MX-MPC2E-3D-P (MPC2E P) on MX240, MX480, and MX960 routers. Output fields are listed in the approximate order in which they appear. Both 1 Gbps and 2. Mar 18, 2015 · To enable SNMP managers in routing instances other than the default routing instance to access SNMP information, include the routing-instance-access statement at the [edit snmp] hierarchy level: [edit snmp]routing-instance-access; If this statement is not included in the SNMP configuration, SNMP managers from routing instances other than the Yes, Junos OS supports SNMP informs as part of its support for SNMPv3. By default, SNMP generates traps when a session moves from a higher state to a lower state. 0) for the Routing Engine in node1: jnxOperatingDescr. When switches learn or unlearn a MAC address, SNMP notifications can be sent to the network management system at regular intervals to record the addition or removal of the MAC address. The MX204 router runs Junos operating system (Junos OS), enabling a wide range of business and residential applications and services, including high-speed transport Corero SmartWall TDD 9. SNMP is widely used in network management for network monitoring. After you configure the non-default management VRF instance, management traffic no longer has to share a routing table with other control traffic or protocol traffic. After committing the configuration, the routes are Sep 23, 2010 · Symptoms. 5. show bgp neighbor. If the temperature goes down before 16:08:10, it would not have the high temperature information by the SNMP trap. 0 Routing table: default. Solution. Some of the commands are: show snmp health-monitor, which displays the health monitor log and alarm information. Jul 11, 2023 · RE: MGMT VRF and me/fxp interfaces : (. This would permit only 172. Field. ping fda1::1 rapid count 25 on vSrx1. 6. The show log ospf-bgp-policy-log command displays information about the routes that the injectpolicy1 policy term analyzes and acts upon. VLAN MAC address Type Age Interfaces. ipRouteTable. user@host> show snmp mib walk jnxOperatingDescr |grep node1 jnxOperatingDescr. The management Ethernet interface (usually named fxp0 or em0) provides the out-of-band management Dec 19, 2011 · Solution. To enable graceful restart, include the graceful-restart statement at the [edit routing-instance instance-name routing-options] or [edit routing-options] hierarchy level. To create the routing table groups, include the passive statement at the [edit routing-options] hierarchy level. . Enter in the routing instance name. To view BGP routing information in the J-Web interface, select Monitor > Routing > BGP Information. Forwarding. With MPLS, only the first device does a routing lookup, and, instead of finding the next-hop, finds the ultimate destination along with a path to that destination. It includes examples of two MIB elements, jnxLsysSpFlowsessSummary and jnxLsysSpFlowsessObjects . The instance name can be primary for the main Dec 18, 2023 · On Junos OS, SNMP uses both standard (developed by the IETF and documented in RFCs) and Juniper Networks enterprise-specific MIBs. x documentation has reached end-of-support (EOS). 9. 9. 3R1, you can confine the management interface in a dedicated management instance by setting a new CLI configuration statement, management-instance, at the Dec 30, 2008 · 2018-12-10: Added a sentence in the solution to clarify accessing MIB objects and performing SNMP operations on default routing instance via an interface on routing instance. SNMP exposes management data in the form Dec 10, 2013 · Description. X. 0; route 10. Aug 10, 2023 · However, when I set the route using set route options command, the configuration is taken but nothing appears in the forwarding table: show | match route. set snmp traceoptions flag all. Use a slash ( / ) to separate the two names (for example, test-ls/test-ri ). Dec 7, 2009 · A routing instance is a collection of routing tables, interfaces and routing protocol parameters. 0 = node1 Routing Engine The values from these MIBs correspond to the Load averages reported in the "show chassis routing-engine" command in the CLI: To get interface-set queue statistics from jnxCosQstatQedPkts MIB with using interface-set SNMP index, use the following command: show snmp mib walk jnxCosQstatQedPkts. 22. To override this, a static route is created with the destination IP of the collector and the next hop of the mgmt_junos routing table. (Optional) Display information for all routing instances whose name begins with this string (for example, cust1, cust11, and cust111 are all displayed when you run the show bgp summary instance cust1 command). The show system uptime command by itself shows system-wide uptime information. Each routing instance has a unique name and a corresponding IP unicast table. 0/0 restrict. fr vc ai dn fp ol cs yk oi dn

Collabora Ltd © 2005-2024. All rights reserved. Privacy Notice. Sitemap.